9902-UDX-FS-OM (V1.1)
9902-UDX-FS PRODUCT MANUAL
3-71
Operating Instructions
9902-UDX-FS Function Menu List and Descriptions
Alarms Setup Controls
Provides controls for setting up controls which screen
for and propagate input program video alarms for
video, audio, and ancillary data defect conditions.
Conditions and alarm status can be propagated as
DashBoard tree-view frame alarms, downloadable .txt
files and/or Syslog IP-based alarms.
Table 3-2
9902-UDX-FS Function Menu List — continued
The Alarms tab has several sub-tabs which allow setting up detection and alarm severity/propagation for input program video
alarms for video, audio, and ancillary data defect conditions (as described and shown below)
Video Alarm Setup sub-tab allows setting up screening engagement and disengagement holdoff
for frozen and/or black video detection on the card’s four SDI inputs (independent for each SDI
input). In the default example settings shown here, engagement and disengagement of alarm
generation occurs 3000 msec after event detect.
Factory default holdoff settings shown here are recommended for at least initial settings. If holdoff
periods are too brief, nuisance alarms may be generated during transitions to and from programs
and interstitials.
Audio Alarm Setup sub-tab allows setting up screening trigger threshold,
engagement and disengagement holdoff for low or missing audio levels on
the card’s embedded audio input channels.
• Levels above the Failover Threshold are considered normal.
• Levels below the Failover Threshold (and exceeding the holdoff) are
considered below normal.
Note: Audio channels screened are from the card SDI that is selected for
the program video/audio path (for example, if SDI A is selected as the
input source on the Input Video tab, the 16 embedded channels
comprising this video/audio input are screened).
Factory default holdoff and threshold settings shown here are
recommended for at least initial settings. If holdoff periods are too
brief (or threshold set too high), nuisance alarms may be generated
during transitions to and from programs and interstitials, as well as
during certain content.