O P E R A T I N G M A N U A L
8 0 0 . 7 4 9 . 2 7 6 1
w w w . c o a c h c o m m . c o m
7 8
E. Use the CU’s navigation buttons to scroll and select
Upload Firmware
from the menu that displays on the CU
LCD.
F. Select
cuimage.bin
in the next menu that displays.
G. Select
Yes
in response to the CU’s “Are you sure you wish to upload firmware?” prompt. A progress bar will
display the progress of the upload.
H. After the upload completes, disconnect the USB drive from the CU and power cycle the device.
Note:
After the update completes, a prompt will display on the CU that confirms the change and asks
“Do you want to reboot the DSP?” You may disregard this prompt. Power cycling the CU at this
step will automatically reboot the DSP, so no response is required.
I. After the CU has finished powering up, ensure it is still connected to the PC via USB cable, then click
Scan for
Devices
in X-Ware to initiate the next phase of the firmware update.
J. The connected CU will display on the tab with an alert message about the incomplete update. Proceed with
the update process in the next step.
8. Click the
Update
button. A progress bar will display.
9. Wait for the device to complete its update process. DO NOT
disconnect the device or click
Abort
until all of the device’s updates
are complete and an “Update Complete” message displays in the
progress bar. Click the
Clear
button to remove that device from the
list.
Note:
When updating CUs, the CUs will reboot; wait for the CU front
panel to display an “Upload Complete” message before clearing the X-Ware screen and continuing to Step 11.
Note:
When updating RTs, wait for the RX and TX LEDs to finish alternating flashes and return to a normal
state before clearing the X-Ware screen and continuing to Step 11. Also, since you should always
update the top (master) CU first, both CUs will display a configuration compatibility/firmware
mismatch message until the bottom (secondary) CU update is completed.
10. Verify the firmware installation by repeating step 7 to rescan the device. Confirm that the rescanned device now
displays the new firmware version number in the software.
11. Disconnect the USB cable from the device without clicking on anything in X-Ware. Once the device is
disconnected, click
Clear/Abort
to remove the device from the Firmware tab.
12. Repeat steps 6–11 above until each Control Unit (CU), Radio Transceiver (RT), and Radio Pack (RP) is updated.
13. Once the update is complete, open your backup CCF in X-Ware by clicking
File
then
Open...
14. Ensure that the CCF is converted and saved in the v1.5 format by clicking
File
then
Save File As...
and saving it to
the cart PC.
15. Close X-Ware, then reopen it, allowing X-Ware to connect to the system and go Live.
Figure 109: CU LCD “Upload Firmware” Menu
Figure 110: Device Firmware In Progress
Figure 111: Connected Device