QCM486 Miniature Protector Connector (MPC)
- 5 –
6.1
Mounting bar kits are for use on
distributing frame verticals which are not
drilled to fit the MPC 5.5-in. mounting
centers. To select appropriate kit (refer to
Table 2).
6.2
Before installing, make sure you have the
right mounting bar kit for installation on the
distributing frame.
6.3
If the frame vertical is 4.8 mm (3/16 in.)
thick, place the spacers provided between frame
vertical and mounting bars.
6.4
Place a 1.2 mm (4 ft.) mounting bar
against the right side of the vertical, with the
short bend of the mounting bar located to the
left (Figure 5).
6.5
Fasten mounting bar to vertical using the
screws provided. Leave 75 mm (3 in.) between
the mounting bar and the guard rail at the
bottom of the frame. Insert screws from right,
through the 50-mm (2-in.) slots in the
mounting bar, into the existing holes in
verticals. Position screws at top, center and
bottom of bar.
6.6
Fasten the connector to the mounting bar
with the screws, nuts and bolts provided. Insert
screws from left into the 12.7-mm (0.5-in.) slots
in the mounting bar, and assemble lock washers
and nuts loosely.
NOTE:
For distance of first MPC from floor or
ladder guard rail, see Figure 7 and Table 3.