display the current
ID address (ID range 1-8), you can press 1-8 channel key to modify the address. After
the modification is completed, press the "
" key to exit. Note: The range of local
ID address is 1-
255. This manual mode can only display or modify the address 1-8. Out of this range,
it can’t be displayed, it can be set by PC upper computer software, the factory default
machine
The address is 1.
3.4.8. Restore factory settings:
Press and hold the "
" button to power up the device. At this time, the "
l"
indicator light flashes green, release the "
" button, the "
" indicator light is
steady green
Color, it means the factory reset is completed.
TECHNICAL PARAMETER:
Model
VS-C203
Access power
AC220V, 50HZ
Output
1 to 8 sets of transfer switches (normally open and normally closed)
Load capacity
single channel 16A, whole machine 50A
Direct control
manual button
External control
DC 5-12V signal external short circuit control
RS-485, RS-232 serial port
Size
W482xD21 OxH44(mm)
Weight
5.0kg
Others
Manual Warranty Card
CONNECTION:
5.1 External level control and level cascade control connection