Rev1.0a | 35/50
CMT2300A
STBY State
In STBY state, the crystal is turned on, the LDO of the digital circuit will also be turned on, the current will be slightly increased, and
the FIFO can be operated. The user can choose whether to output CLKO (system clock) to PIN. Because the crystal and LDO is
turned on, compared to the SLEEP, the time switching from the STBY to transmitting or receiving will be relatively short. Switching
from SLEEP to STBY will be completed after the crystal is turned on and settled. Switching from other state to STBY will be
completed immediately.
RFS State
RFS is a transition state before switching to RX. Except that the receiver RF module is off, the other modules are turned on, and the
current will be larger than STBY. Because PLL has been locked in the RX frequency, RFS cannot switch to TX. Switching from
STBY to RFS probably requires PLL calibration and stability time of 350us. Switching from SLEEP to RFS needs to add the crystal
start-up and stability time. Switching from other state to RFS will be completed immediately.
TFS State
TFS is a transition state before switching to TX. Except that the transmitter RF module is off, the other modules are turned on, and
the current will be larger than STBY. Because PLL has been locked in the TX frequency, TFS cannot switch to RX. Switching from
STBY to TFS probably requires PLL calibration and stability time of 350us. Switching from SLEEP to TFS needs to add the crystal
start-up and settled time. Switching from other state to TFS will be completed immediately.
RX State
All modules on the receiver will be opened in RX state. Switching from RFS to RX requires only 20us. Switching from STBY to RX
needs to add the PLL calibration and settled time of 350us. Switching from SLEEP to RX needs to add the crystal start-up and
settled time. TX can be quickly switched to RX by sending go_switch command. Whether the TX and RX setting frequency is the
same, the user need to wait for the PLL re-calibration and settled time of 350us to switch successfully.
TX State
All modules on the transmitter will be opened in TX state. Switching from TFS to TX requires only 20us. Switching from STBY to TX
needs to add the PLL calibration and settled time of 350us. Switching from SLEEP to TX needs to add the crystal start-up and
settled time. RX can be quickly switched to TX by sending go_switch command. Whether the RX and TX setting frequency is the
same, the user need to wait for the PLL re-calibration and settled time of 350us to switch successfully.