CMT2300A
Rev1.0a | 4/50
www.cmostek.com
1. Electrical Characteristics
V
DD
= 3.3 V, T
OP
= 25 °C, F
RF
= 433.92 MHz, the sensitivity is measured by receiving a PN9 coded data and
matching the impedance to
50Ω under the 0.1%BER standard. Unless otherwise stated, all results are tested on
the CMT2300A-EM evaluation board.
1.1 Recommended Operation Condition
Table 1. Recommended Operation Conditions
Parameter
Symbol
Condition
Min.
Typ.
Max.
Unit
Power voltage
V
DD
1.8
3.6
V
Operating temperature
T
OP
-40
85
℃
Power voltage slope
1
mV/us
1.2 Absolute Maximum Rating
Table 2. Absolute Maximum Ratings
[1]
Parameter
Symbol
Conditions
Min
Max
Unit
Supply Voltage
V
DD
-0.3
3.6
V
Interface Voltage
V
IN
-0.3
V
DD
+0.3
V
Junction Temperature
T
J
-40
125
℃
Storage Temperature
T
STG
-50
150
℃
Soldering Temperature
T
SDR
Lasts at least 30 seconds
255
℃
ESD Rating
[2]
Human Body Model (HBM)
-2
2
kV
Latch-up Current
@ 85
℃
-100
100
mA
Notes:
[1]. Exceeding the Absolute Maximum Ratings may cause permanent damage to the equipment. This value is a pressure
rating and does not imply that the function of the equipment is affected under this pressure condition, but if it is exposed
to absolute maximum ratings for extended periods of time, it may affect equipment reliability.
[2]. The CMT2300A is a high performance RF integrated circuit. The operation and assembly of this chip should only be
performed on a workbench with good ESD protection.
[2].
Caution!
ESD sensitive device. Precaution should be used when handling the device in order
to prevent permanent damage.