![CMC SV008ACtionMaster-2 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/cmc/sv008actionmaster-2/sv008actionmaster-2_installation-and-operating-instructions-manual_2627176031.webp)
Chapter 3 - Parameter List
25
3.2 Function Group 1 [FU1]
Code
Description
Keypad
Display
Setting Range
Units
Factory
Default
Adj.
During
Run
Page
FU1-00
Jump to Desired Code #
F 0
1 to 99
1
3
Yes
39
0
(None)
1
(Forward Prev)
FU1-03
Run Prevention
F 3
2
(Reverse Prev)
-
0
(None)
No
39
0
(Linear)
1
(S-Curve)
2
(U-Curve)
3
(Minimum)
FU1-05
Acceleration Pattern
F 5
4
(Optimum)
-
0
(Linear)
No
39
0
(Linear)
1
(S-Curve)
2
(U-Curve)
3
(Minimum)
FU1-06
Deceleration Pattern
F 6
4
(Optimum)
-
0
(Linear)
No
39
0
(Decel)
1
(DC-Brake)
FU1-07
Stop Mode
F 7
2
(Free-Run)
-
0
(Decel)
No
40
FU1-08
7
DC Injection Braking Frequency
F 8
(FU1-22) to 50/60 [Hz]
0.01
5.00 [Hz]
No
FU1-09
DC Injection Braking On-delay Time
F 9
0 to 60 [sec]
0.01
0.10 [sec]
No
FU1-10
DC Injection Braking Voltage
F 10
0 to 200 [%]
1
50 [%]
No
FU1-11
DC Injection Braking Time
F 11
0 to 60 [sec]
0.1
1.0 [sec]
No
41
FU1-12
Starting DC Injection Braking
Voltage
F 12
0 to 200 [%]
1
50 [%]
No
FU1-13
Starting DC Injection Braking Time
F 13
0.0 to 60.0 [sec]
0.1
0.0 [sec]
No
41
FU1-20
Maximum Frequency
F 20
40.00 to 400.00 [Hz]
0.01
50 / 60 [Hz]
No
FU1-21
Base Frequency
F 21
30.00 to (FU1-20)
0.01
50 / 60 [Hz]
No
FU1-22
Starting Frequency
F 22
0.10 to 10.00 [Hz]
0.01 0.10
[Hz] No
42
0
(No)
FU1-23
Frequency Limit Selection
F 23
1
(Yes)
-
0
(No)
No
FU1-24
8
Low Limit Frequency
F 24
0.00 to (FU1-25)
0.01 0.00
[Hz] No
FU1-25
High Limit Frequency
F 25
(FU1-24) to (FU1-20)
0.01
50 / 60 [Hz]
No
42
0
(Manual)
FU1-26
Manual/Auto Torque Boost
Selection
F 26
1
(Auto)
-
0
(Manual)
No
FU1-27
Torque Boost in Forward Direction
F 27
0.1 2.0
[%] No
FU1-28
Torque Boost in Reverse Direction
F 28
0.0 to 15.0 [%]
0.1 2.0
[%] No
43
7
Code FU1-08 through FU1-11 appears only when FU1-07 is set to ‘DC-brake’.
8
Code FU1-24 through FU1-25 appears only when FU1-23 is set to ‘Yes’.
Содержание SV008ACtionMaster-2
Страница 67: ...Chapter 4 Parameter Description FU2 61 Notes...
Страница 105: ...Chapter 6 Troubleshooting Maintenance 99 Notes...
Страница 109: ...Chapter 7 Options 103 Notes...
Страница 118: ...112...