Chapter 2 - Operation
23
2.4.3 Operation From Keypad
1. Turn the power ON and set the operation and frequency reference to ‘keypad operating mode’.
2. Set the DRV-03 (drv) to 0 (Keypad), and the Frq [Frequency Reference Source Selection] to Keypad-1.
3. Use FUNC,
▲
(Up) key to set the operating frequency to 50.00Hz. When the inverter is not running the
command frequency is displayed.
4. Press the RUN key. The motor will rotate and the keypad will display the output frequency.
5. Press the STOP/RESET key. The motor will decelerate and come to a halt, and the keypad will display
the command frequency.