4
Control Method
V/F Control
Frequency Setting Resolution
Digital Reference: 0.01 Hz (Below 100 Hz), 0.1 Hz (Over 100 Hz)
Analog Reference: 0.03 Hz / 50 Hz
Frequency Accuracy
Digital: 0.01 % of Max. Output Frequency, Analog: 0.1 % of Max. Output Frequency
V/F Ratio
Linear, Square Patter, User V/F
Overload Capacity
150 % of Rated Current for 1 Min. (Characteristic is inversely Proportional to Time)
CO
NTRO
L
Torque Boost
Manual Torque Boost (0 ~ 15 %), Auto Torque Boost
Operation Method
Key / Terminal / Communication Operation
Frequency Setting
Analog: 0 ~ 10V / 4 ~ 20 mA Digital: Keypad
Start Signal
Forward, Reverse
Multi-Step Speed
Up to 8 Speeds Can Be Set (Use Multi-Function Terminal)
Multi Step Accel/Decel Time
0 ~ 9,999 sec, Up to 4 Types Can Be Set and Selected for Each Setting (Use Multi-
Function Terminal), Accel/Decel Pattern: Linear Pattern, U Pattern, S Pattern
Emergency Stop
Interrupts the Output of Inverter
Jog
Jog Operation
Input Sign
al
Fault Reset
Reset Faults When Protective Function is Active
Operating Status
Frequency Level Detection, Overload Alarm, Stalling, Over Voltage, Under Voltage,
Inverter Overheating, Running, Stop, Constant Speed, Speed Searching
Fault Output
Contact Output (A, C, B) – AC250V 1A, DC30V 1A
Output S
ignal
Indicator
Choose One From Output Frequency, Output Current, Output Voltage, DC Voltage
(Output Voltage: 0 ~ 10V)
O
PERATIO
N
Operation Function
DC Braking, Frequency Limit, Frequency Jump, Second Function, Slip
Compensation, Reverse Rotation Prevention, Auto Restart, PID Control
Inverter Trip
Over Voltage, Under Voltage, Over Current, Inverter Overheating, Motor Over
heating, Input/Output Phase Loss, Overload Protection, Communication Error, Loss
of Speed Command, Hardware Fault
Inverter Alarm
Stall Prevention, Overload Alarm
Protectio
n
Momentary Power Loss
Less than 15 msec: Continuous Operation,
More than 15 msec: Auto Restart (Programmable)
Operation Information
Output Frequency, Output Current, Output Voltage, Frequency Value Setting,
Operating Speed, DC Voltage
D
ispla
y
Keypad
Trip Information
Indicates Fault when Protection Function Activated, Memorizes Up to 5 Faults
Ambient Temperature
-10
°
C ~ 40
°
C (14
°
F ~ 104
°
F),
CE Certification:
41 °F ~ 104 °F (5 °C ~ 40 °C)
Storage Temperature
-20
°
C ~ 65
°
C (-4
°
F ~ 149
°
F)
Ambient Humidity
Less Than 90 % RH Max. (Non-Condensing),
CE Certification: 5 ~85% (Non-Condensing)
Altitude / Vibration
Below 1,000 m
·
Below 5.9m/sec
²
(=0.6g)
Application Site
No Corrosive Gas, Combustible Gas, Oil Mist, or Dust
Environ
m
ent
Atmospheric Pressure
70 ~ 106kPa
Cooling Method
Forced Air Cooling
4
4
‘Self-cooling’ for model SV004ACtionMaster -4, SV008ACtionMaster -4.