MAN.234 Rev.3 ENG - Use and maintenance manual S19HD (PRO)
page
31
of
83
RELEASE THE BUTTON AND PROCEED WITH THE MANUAL
MANOEUVRES.
4.4.8
Acoustic warnings
During the use of the MEWP, it is possible to hear the following acoustic
warnings, corresponding to the following signals:
֠
SOUND
Corresponding to:
Continuous acoustic signal
(intermittent in pre-alarm):
when exceeding the maxi-
mum load allowed.
Load limiter light activated on basket
control station and on wired remote
control.
Continuous acoustic signal
(intermittent in pre-alarm):
when exceeding the maxi-
mum travel inclination al-
lowed.
Maximum travel inclination light acti-
vated on basket control station and on
wired remote control.
Table 3: acoustic signals.
4.5
Lithium battery pack recharge (*optional)
For full lithium version (*optional), in order to recharge the battery pack, it
will be necessary to stall the machine.
Then operate according to the following procedure:
1. switch off the electric engine;
2. couple the 110/120/230 V plug (power line) to the connector on the
machine and press the appropriate button of the magnetothermic
switch;
3. now the batteries will be in charge and the charge progress can be
evaluated through the leds on chassis box or on radio control
station.
The charge times are:
BATTERY CHARGE
TIME
0% - 80%
4 h
80%-100%
2 h
With a full charge (100%), the 160 Ah Eco-Battery pack is able to perform
at least 10 work cycles. A work cycle includes the following sequence of
operations:
1) stabilization;
2) complete machine development;
3) complete machine return;
4) destabilization.
AT THE END OF EACH WORKING SESSION AND HOWEVER AT
LEAST EVERY 15 DAYS, IF THE MEWP IS NOT USED,
ABSOLUTELY RECHARGE THE BATTERY PACK.
www.
duma
-rent.com