MAN.234 Rev.3 ENG - Use and maintenance manual S19HD PRO
page
12
of
83
Picture 4b: ignition station in case of hybrid or full lithium version.
In hybrid version and in a full lithium equipment, the electrical box mounted
on the chassis (Picture 4b) changes as below:
•
the green light
5
indicating machine power supply
: it is on
when the SK key is in position I;
•
the control station selector 6
: at left it enables the basket control
station, at right the radio control on the ground.
•
the platform consent light
7
:
if lighted on, it allows the maneu-
vers of the aerial part only with stabilization correctly performed.
•
the stabilization consent light
8
:
if lighted on, it allows the
movement of the outriggers only with the boom and the panto-
graph rested on their supports.
•
the emergency red mushroom-shaped button
EB
that blocks
the machine, removing the power supply to the control circuits.
This button has priority over all other commands; thus, it allows on-
ly manual descent to the ground.
The emergency button has a mechanical locking device; there-
fore, it must be unlocked by turning it clockwise to reactivate
the normal machine working.
•
the
“dead man” stabilizers button
9
:
it must be held pressed to-
gether with other levers of outriggers control station to stabilize or
destabilize.
•
the fuse box;
•
the battery charge indicator
10
;
•
the hour counter
11
.
Before performing any operation, it is necessary to place the
ignition key in position 1.
Picture 5: left side of chassis box.
In all engine equipment, on the left side of this case (Picture 5), you can
find:
6
5
EB
9
7
8
10
11
2
3
4
www.
duma
-rent.com