MODEL CMA-180UC SERVICE & PARTS MANUAL Rev. 1.18B
Page
2
1. Specifications
1.1.
CMA-180UC
WATER CONSUMPTION
PER RACK
.75 GAL.
(2.83 L)
PER HOUR
17.9 GAL.
(67.6 L)
OPERATING CYCLE
WASH TIME-SEC
94
94
RINSE TIME-SEC
16
16
DWELL TIME-SEC
10
10
TOTAL CYCLE
2 MIN.
2 MIN.
OPERATING CAPACITY
RACKS PER HOUR
30
30
WASH TANK CAPACITY
2.5 GAL.
(9.46 L)
PUMP CAPACITY
38 GPM
(144 LPM)
WATER REQUIREMENTS
REQUIRED MINIMUM TEMP. *
110°F
(43°C)
RECOMMENDED TEMP. **
140°F
(60°C)
WATER INLET
½”
1.27cm
DRAIN CONNECTION
1”
2.54cm
RINSE PRESSURE SET
20 PSI
±
5 PSI
1.41 kg/cm
CYCLE TEMPERATURES
2
WASH-°F
150°F -160°F
(65.5°C/71°C)
RINSE -°F
180°F -195°F
(82°C/90°C)
FRAME DIMENSIONS
DEPTH
25”
(63.5 cm)
WIDTH
24”
(60.96 cm)
HEIGHT
33 ¼”
(84.45 cm)
MAX CLEARANCE FOR DISHES
14.5”
(36.8 cm)
ELECTRICAL RATING*
208 VOLTS
1 PH—60 Hz
230 VOLTS
1 PH—60 Hz
33 AMPS
35 AMPS
BOOSTER HEATER
5.3 kW
6.5 kW
WASH PUMP MOTOR
¾ HP
¾ HP
THIS SYSTEM REQUIRES THREE POWER WIRES, WHICH INCLUDES A
CURRENT CARRYING NEUTRAL. AN ADDITIONAL FOURTH WIRE MUST BE
PROVIDED FOR MACHINE GROUND.
SHIPPING WEIGHT
234#
(106 kg)
* For machines having "SAFETY TEMP" feature. ** For faster heat recovery.
METRIC
EQUIVALENT
Содержание CMA-180UC
Страница 13: ...MODEL CMA 180UC SERVICE PARTS MANUAL Rev 1 18B Page 11 2 2 6 Water Tempering Kit ...
Страница 16: ...Operation MODEL CMA 180UC SERVICE PARTS MANUAL Rev 1 18B Page 14 3 3 Operating and Cleaning Instructions ...
Страница 17: ...Operation MODEL CMA 180UC SERVICE PARTS MANUAL Rev 1 18B Page 15 3 4 Preventive Maintenance Chart ...
Страница 40: ...Parts Manual MODEL CMA 180UC SERVICE PARTS MANUAL Rev 1 18B Page 38 5 Electrical Diagram ...
Страница 41: ...Parts Manual MODEL CMA 180UC SERVICE PARTS MANUAL Rev 1 18B Page 39 ...