INSTALLATION

This section shows how to install the CLS CAS 6.

ATTENTION!
TO prEvENT dAmAgE TO ThE CLS CAS 6, uSE ThE  INCLudEd 
CLS CAS 6 SLEEvE. mAkE SurE drAINAgE CONdITIONS ArE 
AdEquATE. ThESE prECAuTIONS muST bE fOLLOwEd, 
OThErwISE ThE wArrANTy wILL bECOmE INvALId!

W

ARNING

Drainage

To minimize the risk of flooding or water logging, install the fixture in a location which is above the level of 
the surrounding area, and make sure drainage conditions are adequate. CLS recommends to use gravel for 
the best drainage conditions. The unit is not designed to withstand high pressure water jets.

Protection from burns and fire

• Do not install the CLS CAS 6 near a heat source.
• Do not install the CLS CAS 6 in a corrosive, flammable or explosive area.
• Do not modify the CLS CAS 6, or install other than genuine parts.
• Do not operate the CLS CAS 6 if the ambient temperature exceeds 40 ºC.
• Do not stare into the LED, this can cause damage to the eyes.

Protection from injury due to falls

• Verify that all covers and mounting hardware are securely fastened.

• Block the access below the work area whenever installing or removing the unit. 

CAbLE INSTALLATION

Cable slack

Allow at least 300 mm of free cable in the installation, so that the CLS CAS 6 is clear for service without 
disconnecting cables.

NOTE!

For protection from potentially lethal electric shock:

• The CLS CAS 6 must be grounded.
• The AC-power supply must be fitted with a fuse or circuit breaker,  ground-fault protection, and a means 
  to isolate the CLS CAS 6 from power during service or when not in use.
• Cables and fixtures must be isolated from power, and steps taken to prevent reconnection, before carrying 
  out any work on them.
• Do not connect the CLS CAS 6 to an electrical dimmer system: doing so can damage the electronics.

Connecting to AC-power

Connect the power cable only on the right positions! See diagram for the colours of all electric cables:

Wire (EU) 

Function 

Marking

Brown 

Live 

    L

Blue 

Neutral 

    N

Yellow/green 

Earth

Obstruction by roots

The further the CLS CAS 6 is located from vegetation such as trees, hedges or bushes, the less chance there 
is that the roots will obstruct the CLS CAS 6 or even cause damage to its cables. If the CLS CAS 6 is located 
close to vegetation, consult a landscape architect about the solutions for the root obstruction.