background image

CLOUD ELECTRONICS LIMITED

5.2 The Destination Field

The destination field is an abbreviated description of the mixer section the command is intended to effect.
In the CX462, there are three possible destinations, the module itself, the microphone channel and the
music channel. Destination field values are:

-    Music:

MU

-    Microphone:

MI

-    Module

:

SY

Where there is the possibility of multiple destinations, such as the CX462 microphones, a sub-destination
is appended to specify the number of the destination. A dot is used to separate the destination from the
sub destination, e.g. 'MI.3' addresses microphone 3.There are four individual microphones numbered 1
to 4.  Individual microphones can only accept 'Mute' and 'Open' commands.

The destination field is at the start of the message, 

immediately

after the header character ("<").  There

should be no whitespaces or other characters between this field and the header character.

5.3 The Command Field

A command field identifies the command to be performed, followed by any parameters, if required.
In the case of the 'Mute' and 'Open' commands, 'M' and 'O', no parameters are required, since the
purpose is just to set the mute or open state .

The other commands set a parameter for the source or level on a particular channel.  Three command
types are available to do this, Absolute (“A”), Up (“U”) and Down (“D”).  For source select commands,
only the absolute command requires a value; for level commands 

all

command types require a

parameter.  Using the absolute command type sets the appropriate parameter to that value. The range
of possible values are:

Level:

0-180 where 0 is the highest gain setting.

Source:

0-6 where 0 is off and 1-6 specify line inputs.

The Up and Down command types will require a value only if the parameter being changed is a level
control.  The value denotes the number of half dB steps that the level should be changed by.  It is
important to note that the level value represents a gain 

reduction

so a step down in the level parameter

will increase the audible output.

The command field is separated from the destination field by a comma, which it should immediately
follow. 

<MU,LA20/>

COMMAND

The command field identifies the action to be performed by the module. In this example, a level
control is being executed.

<MU,LA20/>

DESTINATION

The destination indicates which section the module should act on. In this example the music section
is identified.

4

CDI-S100 Serial Interface Card

Setup And Installation Guide

Содержание CDI-S100

Страница 1: ...CDI S100 Installation Setup Guide Version 1 CDI S100 SERIAL INTERFACE CARD Cloud Electronics Limited Copyright Cloud Electronics Limited 2003 Clearly Better Sound...

Страница 2: ...LIMITED CDI S100 Installation and Setup Guide Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England Phone 44 0 114 244 7051 Fax 44 0 114 242 5462 E mail technical cloud co uk WebSite...

Страница 3: ...CX462 Configuration 3 4 1 Microphone Access controls 3 4 2 Music source select and volume 3 5 Cloud SP v1 Communications protocol 3 5 1 Message Structure 3 5 2 The Destination Field 4 5 3 The Command...

Страница 4: ...M3 screw adjacent to CON7 and M3 screw next to C96 Keep to one side 6 Remove hex spacers from 9 pin sub D socket 7 Screw 25mm hex spacers into screw holes in step 5 8 Connect ribbon cable attached to...

Страница 5: ...the CDI S100 changes the communications mode between hardware handshaking software handshaking and no handshaking modes Hardware handshaking utilises the two dedicated lines Clear To Send CTS and Requ...

Страница 6: ...e music controls between forced analogue and switchable controls AN and SW positions respectively The controls must be switchable to allow the CDI S100 to control them as any other setting will effect...

Страница 7: ...se is just to set the mute or open state The other commands set a parameter for the source or level on a particular channel Three command types are available to do this Absolute A Up U and Down D For...

Страница 8: ...will set the default settings This message sets the default music level to 10dB below the maximum music level 5 6 Data Formats To provide for a broad range of controllers the CDI S100 will accept two...

Страница 9: ...rce commands a lower case absolute message type is always returned 5 9 Example commands 1 Absolute Music Level We would like to set the music level on a unit to 0dBu In order to do this we need to rec...

Страница 10: ...dialog box Click the Settings tab on and press the ASCII Setup button to open the Ascii setup dialog box Set the checkbox labelled Echo typed characters locally Close the Ascii setup and the Properti...

Страница 11: ...Notes...

Отзывы: