V2.1 2021-01
Page 15 of 25
Unit selector ID – Two rotary decimal encoders
provide the unit’s address ID number.
By default the unit’s ID number is on the CCRM 4000
is set “00”.
Secondary units need to be setup with a number that
is non-zero. All Secondary units MUST have unique ID
numbers.
On the other side of the CCRM 4000, there are additional connectors
Description
Connector
Single element CCRM 4000 provides audio out via a
single 3 pin XLR connector
Tri-Element CCRM 4000R provides audio out via a
single RJ45 connector.
IR (Socket 1)
Connects to the IR sensor. This sensor (supplied with
Main units only) is used to initially program the height
of each microphone.
BEZEL (Socket 2)
This RJ12 connector is connected to the Bezel and
senses the home position for the microphone.
IMPORTANT: Do not plug the RJ12 connector into
any other socket else this could result in damaging
the internal pins of the other sockets.
DSP IN (Socket 3)
Connects to the DSP. Receives trigger from the DSP to
deploy the microphones and provides status
indicating mic is in deployed position.
LINK (Socket 4)
Provides trigger for the Secondary CCRM 4000,
receives mic deployment status of Secondary and for
inter-device communication.