4
I. PREPARATION
B. Electrical Connections
Important
Before
connecting the motor leads to the power supply, be sure that the voltage, cycles
and phase shown on the nameplate of the motor correspond to the available power supply.
All Clipper electric motors have overload protectors and are equipped with a reset button on the
motor housing. If, after proper electrical connections are made, the motor will not run, press the reset
button to the overload protector switch.
Power Connections
Connect the power supply to the pigtail leads of the switch. Direct wiring connection is preferred, but
an extension cord with an electrical plug with 30 amp minimum capacity may be used. Connecting
wires should be as short as possible and in one piece. In no case should the connecting wires be
longer than shown in the following table for 5 h.p. single phase motors:
Length Of Wire
Wire Gauge
3 & 5 HP
230v 1PH
5HP
230/460v 3HP
7-1/2HP
230/460v 3HP
12
50’
-NA-
-NA-
10
100’
70’
-NA-
08
150’
110’
140’
06
-NA-
180’
200’
Caution-When wires that are too small gauge or too long are used, loss of power, over heating, or
possible damage to the motor will result. –NA-= Do Not Use Wire Gauge For This Application, Motor
Damage Will Occur and Will Not Be Covered Under Warranty
Ground Connection
Be sure to ground the saw properly before operation. See professional licensed electrician for wiring
and grounding assistance.
Содержание BBH255
Страница 1: ...OWNERS MANUAL Clipper Masonry Saw Models BBH455 BBH255 BBH275 FORM 5316 rev9 00 ...
Страница 6: ...5 I PEPARATION C Wiring Diagram ...
Страница 7: ...6 ...
Страница 18: ...17 V PARTS LIST SECTION D Assembly Drawing ...
Страница 20: ...19 ...
Страница 21: ...20 ...
Страница 22: ...21 ...
Страница 23: ...22 ...
Страница 24: ...23 ...
Страница 25: ...24 ...
Страница 26: ...25 ...
Страница 27: ...26 ...
Страница 28: ...27 NOTES ...