78
EN
Separate accessories
Description
Code
Diameter Ø 80
(mm)
Air-flue split pipe system (with take-off point) +
Diaphragm
8093020
90° curve M-F (6 pieces)
8077410
90° curve M-F (with take-off point)
8077407
90° curve M-F (insulated)
8077408
Extension W. 1000 mm (6 pieces)
8077309
Extension W. 1000 mm (insulated)
8077306
Extension W. 500 mm (6 pieces)
8077308
Extension W. 135 mm (with take-off point)
8077304
Wall outlet terminal
8089501
Internal and external ring nut kit
8091500
Inlet terminal
8089500
45° curve M-F (6 pieces)
8077411
Condensate recovery W. 135 mm
8092800
Manifold
8091400
Tile with joint
8091300
Roof outlet terminal W. 1390 mm
8091201
Condensate recovery Tee
8093300
Inlet/outlet fitting Ø 80/125 mm
8091401
Split pipe system
The split pipe system is supplied with the combustion air inlet
diaphragm which is to be mounted, after the sections have been
eliminated according to the total load loss which is calculated by
summing the load losses of the inlet ducts to those of the outlet
ducts.
1
2
4
5
3
Fig. 31
KEY:
1
Split pipe system with take-off point
2
Inlet diaphragm
3
Air inlet
4
Smoke outlet
5
Take-off point for smoke analysis
Load loss accessory Ø 80 mm
Description
Code
Load loss (mm H
2
O)
24 BF
28 BF
38 BF
Inlet Out-
let
Inlet Out-
let
Inlet Out-
let
90° curve MF
8077410 0,35 0,40 0,45 0,50 0,70 1,50
45° curve MF
8077411 0,30 0,35 0,40 0,45 0,60 1,00
Horizontal exten-
sion W. 1000 mm 8077309 0,20 0,30 0,25 0,35 0,40 0,65
Vertical extension
W. 1000 mm
8077309 0,20 0,10 0,25 0,15 0,30 0,30
Wall terminal
8089501 0,15 0,50 0,20 0,80 0,25 2,00
Condensate
recovery Tee
8093300
-
0,80
-
1,00
-
2,20
Roof outlet termi-
nal (*)
8091200 1,60 0,10 2,00 0,20 4,00 0,40
(*) The losses of the roof outlet terminal at inlet include the mani-
fold code 8091400.
NOTE:
for the boiler to operate correctly it is necessary that a mi-
nimum distance of 0.50 m of the duct is respected with a 90° inlet
curve.
Example: calculation of the load loss of a
24 OF
boiler.
Accessories Ø 80
mm
Code
Quan-
tity
Load loss (mm H
2
O)
Inlet
Outlet
Total
Extension W. 1000
mm (horizontal)
8077309
7
7 x 0,2
-
1,40
Extension W. 1000
mm (horizontal)
8077309
7
-
7 x 0,3
2,10
90° curve
8077410
2
2 x 0,35
-
0,70
90° curve
8077410
2
-
2 x 0,4
0,80
Wall terminal
8089501
2
0,15
0,5
0,65
TOTAL
5,65
(installation permitted since the total of the load loss of the acces-
sories used is less than 9,0 mmH
2
O).
With this total load loss, sections 1 to 6 (inclusive) must be remo-
ved from the inlet diaphragm (2).
2
Fig. 32
No. of sections to be
removed
Total load loss (mm H
2
O)
24 BF
28 BF
38 BF
None
0 ÷ 2,0
0 ÷ 0,8
-
1
2,0 ÷ 3,0
0,8 ÷ 1,5
-
1 ÷ 2
3,0 ÷ 4,0
1,5 ÷ 2,4
0 ÷ 2,0
1 ÷ 3
-
2,4 ÷ 3,2
-
1 ÷ 4
4,0 ÷ 5,0
3,2 ÷ 4,0
2,0 ÷ 4,0
1 ÷ 5
-
4,0 ÷ 4,8
4,0 ÷ 6,0
1 ÷ 6
5,0 ÷ 6,0
4,8 ÷ 5,6
6,0 ÷ 8,0
1 ÷ 7
6,0 ÷ 7,0
5,6 ÷ 6,5
8,0 ÷ 9,0
1 ÷ 8
-
6,5 ÷ 7,3
9,0 ÷ 11,0
1 ÷ 9
7,0 ÷ 8,0
7,3 ÷ 7,8
-
1 ÷ 10
-
7,8 ÷ 8,4
11,0 ÷ 13,0
Entire diaphragm
8.0 -
9.0
(*)
8.4 -
9.5
(*)
13,0 ÷
15,0
(*)
(*) Maximum load loss permitted.
Содержание 24 BF
Страница 10: ...10 FR ...
Страница 49: ...49 FR ...
Страница 58: ...58 EN ...
Страница 97: ...97 EN ...
Страница 98: ...98 ...
Страница 99: ...99 ...
Страница 100: ...Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 ...
Страница 101: ...Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 ...
Страница 102: ...51 ...
Страница 103: ...50 ...
Страница 104: ...49 ...
Страница 143: ...10 ...