Note
Climinox
published on 01/01/2011
(this document can be modified without notice)
General points
ModulAir air conditioners are designed for treating air and must not be used for other
applications. They allow, according to the models, for cooling, heating, humidification,
dehumidification and ventilation.
They can be implemented only by professionals.
Climinox has designed its air conditioners for agricultural purposes. This application
field requires meeting a certain number of sanitary criteria, resistance in a corrosive
environment and safeties.
ModulAir air conditioners are therefore made from stainless steel AISI 304L (or AISI
316L). The exchange surfaces are smooth, the body does not contain any spaces where
grime can be retained. All of the parts of the air conditioner have to be accessible easily, for
cleaning or visual inspection of the state of cleanliness. These operations must be
performed without tools and without disassembling any screws or nuts (accidentally, one of
these elements could escape and end up in food products).
ModulAir range
ModulAir air conditioners are formed from modular elements. This design makes it
possible to provide the machine that responds, exactly, to the precise needs of the
premises to be air conditioned. It also makes it possible to upgrade the air conditioner if the
needs were to change.
This range is broken down according to the architecture and the number of
modules that it comprised of. The coded designation of the air conditioner gives the
model of the air conditioner, its size and its options.
Examples: DF4.5 PL - 5F - 2C - 4V380t – (BH-GT) SF6CS- 12F – 3r2.2EL -
2V220m – (RL)
The 1st code provides info on the geometry:
SF3
: Single flow air conditioner (1 blowing direction), 1 stack of layers.
SF6
: Double
flow air conditioner (1 blowing direction), 2 stacks of layers.
DF3
: Double flow air
conditioner (2 blowing directions), 2 stacks of layers.
DF4.5
: Double flow air conditioner (2
blowing directions), 3 stacks of layers.
Ending
PL
: Ceiling mount.
MU
: Wall mount.
CH
: Frame mounted on the floor.
The 2nd code provides info on the cooling battery:
n
F
: The number of rows in the chilled water battery.
No intervention, on the air conditioner, must be performed
without having stopped and secured the installation
beforehand.
4
/ 14