24
alarm if the name is selected from the
default zone name list when editing the
device. For alarm triggered by the control
panel, the panel will play message “Control
Panel”.
3. Alarm event: The panel will play the alarm
message according to alarm type which
includes: Burglar, Fire, Medical or
Emergency
To ensure the call is successfully received by
the recipient, the recipient should acknowledge
the message by pressing the appropriate
button on his telephone set.
There are 3 buttons to press during a Voice
reporting:
“
1”
– Open a two-way communication channel
with the Control Panel. The Control Panel will
acknowledge this report as successful.
“9”
– Hang up the call, the Control Panel will
acknowledge the report as successful.
“0”
– Hang up the call, the Control Panel will
consider this report as failure and report to the
next destination in the same group.
4.14. Fault Display
The Fault Display option is for you to view the
fault events:
Step 1.
Select
Fault Display
, press OK to
confirm. If fault events The screen will
display:
S T A R T
Step 2.
Press
Down
key to scroll through the
fault events. When all fault events are
displayed, the screen will show:
E N D
Step 3.
You can press
Up
key to scroll back
through the fault events or press
OK
key to exit fault display.
<
<
N
N
O
O
T
T
E
E
>
>
The Control Panel is capable of
detecting following fault events:
Control Panel Low Battery
Control Panel Battery Missing
AC Power Fail
Sensor Out-of-order
Sensor Low Battery
Device and Control Panel
Tamper
Interference Detection
GSM-Related Failure
Network failure
When a fault event exists in system ,
the Fault LED will light up.
4.15. Factory Reset
You can clear all programmed settings for the
Control Panel are return all configuration to
factory default by following the below steps
Step 1.
Power down Control Panel and turn off
the battery switch
Step 2.
Apply power while holding down the
key.
Step 3.
Release the
key when you hear a
beep,”
Enter Code
” will be displayed
along with current firmware version.
Step 4.
Press the
key.
Step 5.
All programmed parameters are reset
to factory default setting.