9
Auto check-in report is made whenever the
Control Panel was powered off, then on again,
or when Auto check-in interval time is changed..
Factory Default is set to
1
hour.
Step 1.
Select
Offset period
and press
OK
to
confirm.
1 h r
2 h r
. . .
1 1 h r
1 2 h r
Step 2.
The screen will display current Offset
period setting. To change the setting,
select a new option and press
OK
to
confirm.
Follow-on Timer
After the Control Panel makes a GSM digital
report to the Central Monitoring Station, the
Central Monitoring Station can choose to enter
a “Listen-in” period according to the Follow-On
timer duration set here. During this period, the
Central Monitoring Station will be able to listen
to what is happening around the Control Panel
through the microphone on the panel.
Step 1.
Select
Follow-on Time
and press
OK
to confirm.
D i s a b l e
1 m i n
3 m i n
5 m i n
N o L i m i t
Step 2.
The screen will display current Follow-
on Timer setting. To change the setting,
select a new option and press
OK
to
confirm.
High Temperature Report
This is for you to set the High Temperature
reporting threshold. If the Control Panel has
learnt in a Temperature Sensor, it will make
High Temperature report and raise alarm when
the temperature exceeds the threshold. When
the temperature drops below set value again,
the Control Panel will stop alarming and send
High Temperature Restore report. Factory
default is set to
Disable
.
Step 1.
Select
High Temp
and press
OK
to
confirm.
D i s a b l e
- 1
0
°
C
0
°
C
. . .
. . .
5 0
°
C
Step 2.
The screen will display current High
Temperature alarm setting. To change
the setting, select a new option and
press
OK
to confirm.
Low Temperature Report
This is for you to set the Low Temperature
reporting threshold. If the Control Panel has
learnt in a Temperature Sensor, it will make
Low Temperature report and raise alarm when
the temperature drops below the threshold.
When the temperature rises above set value
again, the Control Panel will stop alarming and
send Low Temperature Restore report. Factory
default is set to
Disable
.
Step 1.
Select
Low Temp
and press
OK
to
confirm.
D i s a b l e
- 1 0
°
C
0
°
C
. . .
. . .
5 0
°
C
Step 2.
The screen will display current Low
Temperature alarm setting. To change
the setting, select a new option and
press
OK
to confirm.
Bypass Fault
This is for you to set whether you want to
ignore fault events regarding Ethernet or GSM
function. Bypassed fault events will not
displayed or cause the fault LED will to light up
and emit beeps.
Step 1.
Select
External Tamper
and press
OK
to confirm.
D i s a b l e
I P
G S M
Step 2.
Select either disable/IP/GSM and
press
OK
to confirm.
Date & Time
This is for you to set your time zone, date and
time.
Step 1.
Select
Date & Time
and press
OK
to
confirm.
T i m e Z
o
n
e
D a t e & T i m e
Step 2.
The screen will display current time
zone and date/time setting. To change
the time zone, select
Time Zone
and