14
expired and no correct PIN code
has been entered, the Control
Panel will activate its built-in
siren immediately to remind the
user the delay period has
expired.
If the Control Panel is not
disarmed within 30 seconds
after the delay period expires, a
Burglar Alarm
will be reported
and the external sirens included
in the Control Panel will also be
activated. Disarming the Control
Panel within the 30 second
period will return the system to
Disarm mode and silence the
built-in siren. No alarm event will
be reported.
When the system is in Disarm
mode, if a “
Entry
” is triggered,
the Control Panel will make a
“
ding-dong
” Door Chime sound
(if Door Chime function is not
disabled).
Away Entry
When the system is in Away
Arm, if an “
Away
Entry
” device
is triggered, the Control Panel
will start an Entry Delay
countdown timer for the user to
disarm the system.
After the delay period has
expired and no correct PIN code
has been entered, the Control
Panel will activate its built-in
siren immediately to remind the
user the delay period has
expired.
If the Control Panel is not
disarmed within 30 seconds
after the delay period expires, a
Burglar Alarm
will be reported
and the external sirens included
in the Control Panel will also be
activated. Disarming the Control
Panel within the 30 second
period will return the system to
Disarm mode and silence the
built-in siren. No alarm event will
be reported.
When the system is in Disarm
mode, if a “
Entry
” is triggered,
the Control Panel will make a
“
ding-dong
” Door Chime sound
(if Door Chime function is not
disabled).
When the system is in any
Home Arm mode, if an “
Away
Entry
” device is triggered, the
Control Panel will not respond.
During the Entry Delay or Exit
Delay period, if an
Away Entry
device is triggered, the Control
Panel will not respond
24 Hour
The
24 Hour
device is active all
the time and does not have to
be armed or disarmed. An Event
Code of
#130
will be reported
with trigger.
Fire
The
Fire
device is active all the
time and does not have to be
armed or disarmed. An Event
Code of
#111
will be reported
with trigger.
Medical Emergency
A
Medical Emergency
device
is active all the time and does
not have to be armed or
disarmed. An Event Code of
#101
will be reported with trigger.
Water
The
Water
device
is active all
the time and does not have to
be armed or disarmed. An
Event Code of
#154
will be
reported with trigger.
Set/Unset (For Door Contact Only)
If the Door Contact is set to
Set/Unset, the system will be
disarmed when the Door
Contract is triggered, and armed
when Door Contact is closed.
Silent Panic
If the device attribute is set as
Silent Panic
, when the device
is activated, the Control Panel
will report a
Slient Panic
alarm
without sounding an audible
Содержание VST-2752