![Climax Vesta ESGW Series Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/climax/vesta-esgw-series/vesta-esgw-series_installation-manual_2624893051.webp)
48
All events: the system will report any event to this destination.
Alarm events: the system will only report alarm event to this destination.
Status events: the system will only report status event(mode change /fault/auto cheeck-in..)
to this destination.
Group
Select a group for your report destination The system will make report according to the
following settings:
Group with higher priority will be reported first: Ex: Group 1
Group 2
Group 3
….
If reporting to the first destination in a group fails, the system will move on to the next
report destination in the group.
If reporting to one of the report destinations in a group is successful, the system will
consider reporting to this group successful and stop reporting to rest of the destinations
in the group. It will then move on to report to the next group.
If reporting to all destinations in a group fails, the system will retry the reporting
according to retry times set below. If reporting is still unsuccessful after retries, the
system will move on to report the the next group according to Essential/Optional setting
below.
After completing a round of reporting (From Group 1
Group 2
…..
Group5), If there
is any group set as Essential which has not received report successfully, the system
will restart the reporting cycle to retry reporting until every group set as Essential is
reported successfully.
Essential/Optional
Essential: the system will report to any group set as
Essential
. The system will never give
up trying to report to any group set as Essential until at least one of the
destinations in every Essential group successfully receives the report. Group 1
is always set as
Essential
and cannot be changed.
Optional: The system will only report to group set as
Optional
when reporting to its
previous group failes. For example: if Group 3 is set is optional, the Control
Panel will only report to Group 3 if reporting to Group 2 fails.
1 Retry/ 3 Retry/ 5 Retry/ 10 Retry/ 99 Retry:
If the no report destination in a group could be reached, the system will retry the report
according to the retries times set here.