![Climax Vesta ESGW Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/climax/vesta-esgw-series/vesta-esgw-series_installation-manual_2624893016.webp)
13
Control Panel will report the arm/disarm event by the particular device
Latch Reprot OFF = Whenever the system is armed, home armed or disarmed, the
Control Panel will NOT report the event.
Set/Unset: For Door Contact only. This function allows Door Contact to control system
mode..
Normal Close = The system will be armed when the Door Contact is opened, and
disarmed when Door Contact is closed.
Normal Open = The system will be armed when the Door Contact is closed, and
disarmed when Door Contact is open.
24H: this function enables the sensor to report an selected alarm event whenever it is
triggered regardless of system mode..
Disarm/ Full/ Home 1/ Home 2/ Home 3 response: if the system is in the disarm /
Full/home1//home2/home3 mode, when a sensor is triggered, it will respond according
to the attribute you set.
Trigger Response: When the device is triggered, the Control Panel will activated
pre-programmed scene setting. Please refer to
Scene
webpage for detail.
Exit: if
No Response
is ticked, the sensor does not repond to any trigger when the
system under Exit Delay Time 1/2. If
No Response
is not ticked, the sensor will raise
burglar alarm and report immediately when triggered during Exit Delay Timer.
Attribute List:
No Response
When a sensor with
No Response
is triggered, the Control Panel will not
respond.
Start Entry Delay 1
/
Start Entry Delay 2
When the system is under Full Arm or Home Arm mode, if a sensor with
Start
Entry Delay 1/2
attribute is triggered, the system will start an entry countdown
period to give enough time to disarm the system.
When the Control Panel is in the Disarm mode, if a sensor with
Start Entry Delay
1/2
attribute is triggered, the system will immediately report a burglar interior
alarm (
CID code: 132
).
When the Control Panel is in the Full Arm mode, if a sensor with
Start Entry
Delay 1/2
attribute is triggered, the Entry Delay 1/2 timer starts counting down.
If no correct pin code is entered during the entry delay timer to disarm the system,
the Control Panel will report a burglar perimeter alarm (
CID code:131
)
immediately after entry delay timer 1/2 expires.
When the Control Panel is in the Home Arm 1/2/3 mode, if a sensor with
Start
Entry Delay 1/2
attribute is triggered, the Entry Delay 1/2 timer starts counting
down. If no correct pin code is entered during the entry delay period to disam
the system, the Control Panel will report a burglar interior alarm (
CID code: 132
)
immediately after entry delay timer 1/2 expires.
Chime
When a sensor set to
Chime
is activated, the system will sound a Ding-Dong
Door Chime sound to indicate.
Burglar Follow
When the system is in Full Arm or Home Arm mode mode, if a sensor set to
Содержание Vesta ESGW Series
Страница 1: ...November 28 2019...