32
the setting of the Auto Check-in Report.
For example, if
Offset
Period
is set to 2 Hours, and
Auto Check-in Report
is set to 3
Days, the Control Panel will transmit an event code 602 to the CMS after 2 hours, and
then report 602 event code periodically at a regular intervals of 3 days.
Options available are
1 Hour, 2 Hours, 3 Hours, 4 Hours, 6 Hours, 8 Hours, 12
Hours.
IR Camera Resolution of Alarm Images
:
This is to select the resolution and number
of pictures taken by PIR Camera when the camera detects a movement in armed
mode.
Options available are
320x240x3 images, 320x240x6 images and 640x320x3
images.(Default)
Outdoor IR Camera in Greysclae
:
This is to select whether pictures from Outdoor PIR
Camera should be taken in greyscale instead of color pictures.
Options available are:
Disable
(Color Picture) and
Enable
(Greyscale picture)
Area Setting
Area
: operation area
Final Door
:
when the system is under away arming with Final Door set to On and a
Door Contact set as Entry device, then, the system will automatically full arm the
system once this Door Contact is detected as closed, event if the count-down period is
not yet complete.
Arm Fault Type
: this option is for you to choose how the system should respond when
it is being armed under fault condition.
- Confirm: The panel will first display a
“Mode Change Fault” message. Arming again
within 10 seconds will force arm the system.
- Direct Confirm: The system will be force armed directly and report an event.
Tamper Alarm
: this is for you to choose whether the learnt-in external siren should
sound alarm when the tamper is triggered.
- Full Arm: when tamper is triggered under Full arm mode, Control Panel raises a local
alarm and sends report to the monitoring center. While under others modes (Home
arm/ Alarm off modes, etc.), the siren does not sound nor any report will be sent
- Always: Control Panel raises a local alarm
for tamper-trigger in all modes.
Mobility
: this is for you to choose whether the Control Panel should report triggering of
Door Contact and PIR Sensors under Disarm Mode.
- On: Whenever a Door Contact or PIR Sensor is triggered under Disarm Mode, the
Control Panel will send a report
- Off: The Control Panel will not respond to Door Contact and PIR trigger under Disarm
Mode.
Supervision Check
: this option is used to enable system supervision function. When
ON
is selected, the Control Panel will be able to receive the supervision signals from
the devices to monitor their condition.
Time Setting
Supervision Timer
: this is for you to set a perdiod that the Control Panel should be
able to receive the check-in signals form the devices. If the Control Panel fails to
receive a supervision signal from a device within the preset period, it will report a CID
event code (147) accordingly.
Entry Delay 1 for Full Arm
: this is for you to set Entry Delay Timer for full arm mode. It
is allowed to use correct Pin code to disarm the full alarm mode and the alarm reporting
Содержание Vesta ESGW Series