Climax Vesta ESGW Series Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

November 28, 2019   

Содержание Vesta ESGW Series

Страница 1: ...November 28 2019...

Страница 2: ..._____________________________________________________________ 21 5 6 PSS CONTROL ___________________________________________________________________ 22 5 7 UPIC CONTROL________________________________...

Страница 3: ...__________ 58 8 14 FACTORY RESET _________________________________________________________________ 59 8 15 BACKUP RESTORE ______________________________________________________________ 60 8 16 SYSTEM...

Страница 4: ...with all ZigBee devices of same protocol on the market produced by other manufacturers The advanced IP Security System with fully integrated TCP IP technology and Ethernet connectivity is able to tak...

Страница 5: ...r Factory Reset LED Red On Away Arm Red Flash Home Arm Blue On Disarm 2 Network LED Amber Amber On Network Cable Unplugged and WiFi Disconnected Amber Flash Disconnected from Server Off Network Normal...

Страница 6: ...for standard version 2 3 System Requirements The system requires a TCP IP network environment for you to connect to the Control Panel for system programming Hardware requirement for programming the p...

Страница 7: ...configuration and operation of Control Panel via Ethernet connect the IP cable to the RJ 45 connector Step 2 Connect the Power Adaptor to a Wall Outlet and the other end to the Control Panel After se...

Страница 8: ...displayed on your desktop Step 5 Double click on the Finder exe to start the software Finder will automatically search for control panel on the LAN and display its information If available the panel s...

Страница 9: ...ly change LanType to Static After finish changing network setting enter the user name default admin and password default cX HsA 7F1 then click OK to confirm The user name and password can be changed l...

Страница 10: ...click on Open Webpage to connect to panel webpage Alternatively enter the Control Panel IP address displayed in Finder into your browser s address section and proceed Step 2 Enter the User name Passwo...

Страница 11: ...mation according to different panel model and MAC address I IM MP PO OR RT TA AN NT T N NO OT TE E If the default login password is not changed webpage access will be disabled 1 hour after power on Re...

Страница 12: ...5 1 1 Add Sensor Step 1 Click on Learning Inclusion on the tool bar and then the following screen will be displayed Step 2 Click on Start Step 3 The Control Panel will automatically search for devices...

Страница 13: ...d Device section as below 5 1 2 Local Learning Press and hold the Function Button at the top of Control Panel for 10 seconds to enter learning mode then transmit signal from your accessory devices Whe...

Страница 14: ...tep 2 You device information and setting will be displayed Programming the settings according to instructions below and click OK when completed to confirm change N NO OT TE E Press Default to reset al...

Страница 15: ...ct the Device zone number Bybass this function allows user to deactivate bypass the selected device If bypassed then the Control Panel will not respond at all when the sensor is triggered If bypassed...

Страница 16: ...hen a sensor with No Response is triggered the Control Panel will not respond Start Entry Delay 1 Start Entry Delay 2 When the system is under Full Arm or Home Arm mode if a sensor with Start Entry De...

Страница 17: ...stem is under Full arm or Home Arm Disarm Entry Time mode if a sensor set to Burglar Instant is triggered the Control Panel will report a burglar alarm immediately Burglar Outdoor When the system is i...

Страница 18: ...15 5 1 4 Delete Devices Step 1 To delete a sensor choose Delete under Panel section Step 2 A message Delete success is displayed and the sensor you choose is deleted successfully...

Страница 19: ...ly from panel AC powered ZigBee devices do not have such limits and you can use Identify function anytime Step 1 Click Identify under the Device List after the device column entry Step 2 If the ZigBee...

Страница 20: ...le menu click Add Learn Rule Step 2 You will see the Add Learn Rule menu Step 3 Select Area and Zone number for this device Step 4 Select ZigBee Step 5 Key in the ZigBee MAC info Step 6 Select a ZigBe...

Страница 21: ...still need to follow the instruction in 5 1 1 Add Sensor to complete the learning process Backup Device List to Learn Rule You can choose to import learn rule from current learnt in ZigBee devices St...

Страница 22: ...te that it is safe to install the particular sensor in the location Time time informaiton Area operation area Zone device zone Type device type Name device name Rssi the signal strength between Contro...

Страница 23: ...1 Click on Exclusion and click on Start to start the procedure Then the Panel will enter the removing mode Step 2 Refer to the Z Wave device manual to transmit signal Step 3 Select the desired Z Wave...

Страница 24: ...Then the inserted Z Wave dongle is reset to factory default and all Z Wave devices will be removed automatically The Control Panel Home ID will also be changed automatically for a newly added Z Wave d...

Страница 25: ...e is designed to control edit delete an added power switch 5 6 1 Edit PSS Click Edit to further edit attributes of power switches Step 1 To program the power switch select PSS Control Edit menu to edi...

Страница 26: ...23 5 6 2 Delete PSS Click Delete to delete power switches 5 6 3 Control PSS Click Switch On Switch Off to turn on off power switches Or click Switch Toggle to control the power switch status...

Страница 27: ...cluded in Control Panel Step 1 Refer to UPIC manual to complete IR signal learning of Off Heating and Cooling command for air conditioner Step 2 Use the drop down menu to select Off Heating or Cooling...

Страница 28: ...ngth setting Please refer to IP Camera manual for detail For PIR Camera Video Camera you can choose to take the picture video without activating the camera s flash Picture and video captured by PIR Ca...

Страница 29: ...pture picture or video PIR camera A picture will be captured upon request PIR Video Camera A 10 second video will be recorded upon request IP Camera The IP Camera will record a video according to its...

Страница 30: ...view details N NO OT TE E If the number of captured events exceeds 100 the oldest record will be replaced the latest one If users intend to receive captured pictures and video from IR cameras on cell...

Страница 31: ...Step 2 Click Switch On or Switch Off to turn on or off one group of power switches 5 9 2 Device Edit Delete Step 1 Check the groups which you wish to assign the power switch This is a multiple choice...

Страница 32: ...dually 6 1 Panel Condition In the Panel Section user can arm disarm or partially arm the system Besides it displays the current Panel Status Device Information Panel Control Select a choice to arm dis...

Страница 33: ...date the device information periodically However in order to show the current status you must reload the screen to refresh the display Area operation area Zone device zone Type device type Name device...

Страница 34: ...lable are Disable 5 Min 10 Min 15 Min up to 4 Weeks Auto Check in Offset Period This is to set the time delay before the first Auto Check In report to be made After power is supplied or re supplied to...

Страница 35: ...force arm the system Direct Confirm The system will be force armed directly and report an event Tamper Alarm this is for you to choose whether the learnt in external siren should sound alarm when the...

Страница 36: ...period you set in Entry Delay 1 for Home Arm On the other hand if the correct Pin code has not entered during the period Control Panel raises an alarm and sends alarm report If Door Contact DC or PIR...

Страница 37: ...ry Exit Only Final Beeps This is for you to determine when the system should start warning beep during Entry or Exit countdown timer For example if the setting is set to 5 seconds the system will only...

Страница 38: ...them afterwards The procedure is similar for both situations 17 alphanumeric characters are available per name Latch this is to program the Latch Key Reporting feature for all users and any arming di...

Страница 39: ...ou can also enter the Network information manually for IP Address Subnet Mask Default Gateway Default DNS 1 and Default DNS 2 Please make sure that you have obtained all required values according to y...

Страница 40: ...wireless access points Select the desired access point and click Add to connect to wireless network 2 Enter the wireless information manually and click OK to connect 3 Use the WPS function to connect...

Страница 41: ...PnP Port Redirect The device will try to find an UPnP supported router and set up the port to redirect to the router Port Forwarding Port forwarding function allows you to configure specific communica...

Страница 42: ...trator Log in Name and Password when accessing this web page Please note the Caps for your Log in Name and Password Step 1 Enter the preferred Login in Name Step 2 Enter the preferred Password in the...

Страница 43: ...5 Select the corresponding action rules in the Execution field Area Select either Area 1 or Area 2 Rule Condition Empty if the rule condition is set as Empty the system will follow the schedule time a...

Страница 44: ...pond accordingly Temperature Above if the rule condition is set as Temperature Above when the sensor specified by selecting the zone number detects the temperature degree above the point that you sele...

Страница 45: ...ule Schedule Always if the rule schedule is set as Always the system will always follow rule schedule to respond accordingly Schedule Once if the rule condition is set as Schedule Once the system will...

Страница 46: ...o the group selected select will be switched off Group Switch On devices belonging to the group selected will be switched on Mode Change the system will change to the mode Disarm Full Arm Home Arm 1 H...

Страница 47: ...UPIC and specified zone will transmit Off Heat Cool command to the air conditioner as programmed Hue Control Adjust the hue and saturation of the Philips Hue at sepecified zone as programmed Trigger A...

Страница 48: ...8 2 Home Automation For example you can set a scene to control multiple lightings then set your Remote Controller to activate the scene when the button is pressed or set a Home Automation Rule to acti...

Страница 49: ...46 included in one scene Step 6 Click Done Step 7 Click OK at bottom of webpage to confirm the new scene setting...

Страница 50: ...at ip Account Number server ip port CID Report via IP in SIA format ip Account Number server ip port SIA Report via IP in CSV format ip Account Number server ip port CSV Report via IP in CSV format in...

Страница 51: ...reporting is still unsuccessful after retries the system will move on to report the the next group according to Essential Optional setting below After completing a round of reporting From Group 1 Gro...

Страница 52: ...emporary Code by tick the Latch Option box and press OK to confirm the settings Installer Code This function is currently disabled Area Each Area has different Duress Code Master Code and Temporary Co...

Страница 53: ...ed and needs to be reset for a new Temporary user The Temporary Code consists of 4 digits and is not activated as default by the factory Latch Option This is to program the Latch Key Reporting feature...

Страница 54: ...the mail account name max 30 digits alphabets From set the email address according to your mail sever and account name If your mail server supports other email address you can enter the email address...

Страница 55: ...dia Upload function sets the upload destination for video clips captured by IP Camera URL 1 5 Upload destination for the video clips Prefix The prefix assigned the file name of captured video clip for...

Страница 56: ...ling The polling function enables the Control Panel to query the destiation you set URL1 or URL2 in turn as to whether it has any data to transmit URL URL2 ip server port path Interval interval time o...

Страница 57: ...54 8 9 XMPP XMPP setting enables the Control Panel to query the set destination This setting is required for the Control Panel to connect to server for further remote control...

Страница 58: ...e Time set current month date and time Time Zone choose your time zone and then the system will calculate the daylight saving time automatically if necessary Internet Time the system will automaticall...

Страница 59: ...56 8 11 Dynamic DNS It is used to get your real public IP address on the internet Dynamic DNS Server http checkip dyndns org...

Страница 60: ...is for you to test the Control Panel internet connection Step 1 Enter the URL destination you want to test connection to Step 2 Enter the test interval Step 3 Click OK You can check the test connect...

Страница 61: ...t firmware file unzipped image bin file in your PC Step 2 Press Apply to upload the latest firmware It will takes about 2 5 mins to load the file onto the Control Panel Step 3 Wait for 1 min and do NO...

Страница 62: ...settings Otherwise the system will reset its value back to factory default Step 2 Press Yes to continue the Reset procedure Step 3 Wait for 1 min and do NOT power off during this time Step 4 Once rese...

Страница 63: ...15 1 Backup Data Yan can backup all programmed data and save these programmed values into a file Step 1 Click Download configuration file Step 2 A bin file will be downloaded into your computer contai...

Страница 64: ...61 8 16 System Log The sytem log webpage logs the control panel s detail system operation history System Log File Download Click to download a detail log files into your computer for more information...

Страница 65: ...it will take a 10 second video clip You can also request the PIR Camera to take a picture and PIR Video Camera to take a 10 second video clip manually Caputred events will be displayed in this page w...

Страница 66: ...iggered events by the control panel by recording the events CID event code and report status Reload Click to refresh the page content Limit of Items Click the drop down menu on the pageto select the n...

Страница 67: ...ge records specific actions performed by the Control Panel and accessory devices Reload Click to refresh the page content Limit of Items Click the drop down menu on the pageto select the numbers of ca...

Страница 68: ...emperature Sensor the update history power consumption or temperature ireading will be displayed under this page the current info is also displayed under Panel and PSS Control Reload Click to refresh...

Страница 69: ...18H Q Event qualifier which gives specific event information XYZ Event code 3 Hex digits 0 9 B F GG Group Partition number 00H or Area Number 00 panel 01 area 1 xx area xx C1C2C3 1 For devices zone C1...

Страница 70: ...erimeter When a device set as Entry is triggered in the arm mode 132 Burglar Interior When a device set at Entry is triggered in the home mode 136 Burglar Outdoor When any device set at Burglar Outdoo...

Страница 71: ...ery Sensor Battery Normal When the battery voltage of any one of the devices is low When any device s battery restores voltage 400 Arm Disarm by Remote Controller When the system is armed or disarmed...