background image

OPERATING INSTRUCTIONS

CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS

9

10

CONTROL PANEL BUTTONS

1) Power On and Off - Press the POWER button once to manually turn the unit on. Press 

the POWER button once more to turn the unit off.

2) Mode Selection - Press the MODE Button repeatedly to cycle between the different 

modes: Auto mode, Air Conditioner, Dehumidifier, Fan only, and Heater.

3) Fan Speed Control - Press the FAN SPEED Button to cycle through the different fan 

speeds: High, Medium, and Low. The fan speed can be visually distinguished by the 

speed of the fan icon on the front panel. There is an additional auto speed setting that is 

enabled in only heating and cooling modes. This speed is next setting after low when 

pressing the speed control button. The speeds will cycle through in this order: High, 

Medium, Low, Auto. Each change in speed will be associated with a “beep” sound from 

the unit.

4) Temperature - Select the desired temperature by pressing either     or     key when using 

the unit in cooling or heating mode. The temperature indicator flashes to display the desired 

temperature setting. After the temperature is set, the unit will display this temperature 

setting until it is changed by the user. The multi-color display shows temperature in Celsius 

or Fahrenheit. Pressing the      and     buttons simultaneously will change the temperature 

select between °F and °C.

5) Timer - To program the timer, press the TIMER ON button until the display shows a 

flashing “         ”. Press the     or     buttons to change the clock to the desired time for the 

unit to automatically turn on.

Press the TIMER OFF button and the display on the unit will flash “       ”. Press the    or   

buttons to change the clock to the desired time for the unit to automatically turn off. The 

TIMER OFF indicator will flash for 3 seconds to activate the times you programmed.

NOTE: The timer will also remember your settings when it is set. If you set the timer while in 

Air Conditioning mode, the timer will automatically turn the unit on and off in air 

conditioning mode according to the desired programmed times. The timer will also 

remember the temperature settings, fan speed, and oscillation setting. The timer works 

when the unit is in Air Conditioner mode, Heating mode, Dehumidifier mode, Fan mode, and 

Auto mode

OPERATING THE UNIT USING THE CONTROL PANEL 

Air Conditioner Mode

1) Install the exhaust hoses and window kit properly (see pages 5,6 & 7).

2) Plug the Power Cord into an electrical outlet.

3) Turn on the unit by pressing the POWER button on the control panel.

4) Press the Mode button until the “   ” icon appears on the Multi-color display

5) Press the    or     buttons until the desired room temperature appears on the control panel

display. The temperature ranges from 61°F - 88 °F (16 °C - 31 °C).

6) Select the desired fan speed by pressing the FAN SPEED button.

NOTE: During hot days, the unit will cool the room most efficiently by setting the tem-

perature at the lowest setting and the fan speed on high. Reducing the length of the 

exhaust duct, insulating the exhaust hose and window kit, and keeping direct sunlight 

to a minimum will also improve the cooling efficiency.

NOTE: When the unit is running on cooling mode, the exhaust hoses are required and 

must be vented outside using the supplied window kit.

Dehumidifier Mode

1) Install the exhaust hoses and window kit properly (see pages 5,6 & 7).

2) Plug the Power Cord into an electrical outlet.

3) Turn on the unit by pressing the POWER Button on the control panel.

4) Press the MODE button until the “   ” appears on the control panel display.

NOTE: The unit operates at low fan speed during dehumidifier mode. The unit cools 

room slightly during the dehumidification. Keep the windows and doors closed to aid 

the effectiveness of the unit in removing the moisture from the room.

NOTE: When the unit is running on dehumidifier mode, the exhaust hoses are required 

and must be vented outside using the supplied window kit.

NOTE: The unit will not perform in dehumidifier mode when the room temperature is 

lower than 61°F .

Fan Mode

1) Plug the Power Cord into an electrical outlet.

2) Turn on the unit by pressing the POWER button on the control panel.

3) Press the MODE button until the “    ” icon appears on the control panel display.

4) Select the fan speed by pressing the FAN SPEED button.

5) To circulate more air, press the SWING button on the remote control. The louvers 

will oscillate which moves the louvers up and down to increase air circulation.

NOTE: It is not necessary for the exhaust hoses and window kit to be installed to 

operate the unit in fan mode.

Heating Mode

1) Install the exhaust hoses and window kit properly (see pages 5,6 & 7).

2) Plug the Power Cord into an electrical outlet.

3) Turn on the unit by pressing the POWER button on the control panel.

4) Press the MODE button until the “   “  icon appears on the control panel display.

5) Press the     or      buttons until the desired room temperature appears on the 

control panel display. The temperature ranges from 61°F - 88 °F (16 °C - 31 °C).

6) Select the fan speed by pressing the FAN SPEED button. It is recommended to set 

the fan speed to low.

NOTE: When heat mode is selected, the unit will shut down for 3-5 minutes, then start 

in heating mode.

NOTE: When the unit is running on heating mode, the exhaust hoses are required and 

must be vented outside using the supplied window kit.

 

Содержание CR13000-PAC

Страница 1: ...ules and instructions before operating this equipment THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY Please keep this manual for future reference Portable Air Conditioner ClimateRight USA Questions o...

Страница 2: ...___ Date Purchased _________________________________________________ Serial Number located on back of unit ______________________________ IMPORTANT INSTRUCTIONS Before installing and using your portab...

Страница 3: ...ing recommendations WARNING 1 DO NOT press the TEST button while the air conditioner is operating 2 The TEST and RESET buttons should not be used as ON and OFF switches 3 The cord and plug are not int...

Страница 4: ...to properly fit the opening 7 Attached the window kit adapters to the window kit Close the window or door tightly Your Portable Air Conditioner is now ready to cool NOTE When using the venting system...

Страница 5: ...cover on the back of the unit and install the square air intake vent with removable washable filter For Single Hose Window Kit Installation To install the window kit follow the same directions on page...

Страница 6: ...ppears on the Multi color display 5 Press the or buttons until the desired room temperature appears on the control panel display The temperature ranges from 61 F 88 F 16 C 31 C 6 Select the desired fa...

Страница 7: ...when the compressor turns on The icon will turn off when the compressor shuts off Emergency Condensate Holding Tank When the room temperature is low and the indoor humidity is high the air conditioner...

Страница 8: ...illate up and down The bottom left square of the remote control display will show the icon when oscillation SWING is selected 7 TIMER To program the timer first press the T ON button Once T ON is pres...

Страница 9: ...over used salvaged or refurbished products As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above lim...

Отзывы: