background image

PACKAGE CONTENTS

Model: CR13000-PAC

Portable Air Conditioner Unit(1)
Exhaust Hoses (2)
Hose Adapters (2)
Window Kit Adapter (2)
Air Intake and Outlet Covers (2)
Remote Control (1)

AAA Batteries (2)
Window Kit 
    - 4 Sliding Panels (1 dual hose panel, 
      1 single hose panel, 2 extension panels) 
    - Air Intake Vent for Single Hose Installation
      (Additional Accessory) (1)
Owner’s Manual

SPECIFICATIONS

• The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.
• Noise level is measured at a distance of 3.28 ft away from the front of the unit, when

   the unit is in cooling mode.
• Power consumption is measured when the fan runs at the highest speed setting.
• These specifications are for reference only. For actual data, please refer to the rating

   label on the back of the unit.
•  If the environment temperature is higher than the max operating temperature or lower

   than the minimum operating temperature, the air conditioner may not work properly.

1

2

CLIMATERIGHT

®

 CR13000-PAC Portable Air Conditioner with Heat Pump 

Thank you for choosing a ClimateRight

®

 product. This owner’s manual will provide you 

with valuable information necessary for the proper care and maintenance of your new 

product. Please take a few moments to thoroughly read the instructions and familiarize 

yourself with all the operational aspects of your new ClimateRight

®

 Air Portable Air 

Conditioner with Heat Pump.

For your own records, please attach a copy of your sales receipt to this manual. Also, 

write the store name/location, date purchased, and serial number below:

Store Name: ____________________________________________________ 

Location: ______________________________________________________ 

Date Purchased: _________________________________________________ 

Serial Number (located on back of unit): ______________________________

IMPORTANT INSTRUCTIONS

Before installing and using your portable air conditioner, please read this owner’s 

manual carefully. Store this manual in a safe place for future reference.

1)   Always place the unit on a level surface.
2)   Never use or store gasoline or other flammable vapor or liquid near this unit unless

      instructed by this manual.
3)   Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block

      or cover air inlet or outlet grilles.
4)   The unit must be connected to a correctly grounded power supply.
5)   Do not start or stop the unit by inserting or pulling out the power plug.
6)   Do not use an adapter plug or extension cord.
7)   Do not use the unit in the immediate surroundings of a bath, a shower or a 

      swimming pool.

8)   Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills
      unless instructed by this manual.
9)   Do not let children play near this unit.
10) Always inspect the cord for signs of damage before use. If the power cord is 

      damaged, it must be replaced by the manufacturer or a qualified service technician.
11) When cleaning the unit, always turn the unit off and unplug the power cord.
12) When the unit is not in use, always remove the venting kit from window.
13) Do Not Mix Old And New Batteries. Do Not Mix Alkaline, Standard (Carbon - Zinc),

      or Rechargeable (Nickel - Cadmium) Batteries.

Model

CR13000-PAC

Cooling Capacity

13,000 BTU/H 

Heating Capacity

12,500 BTU/H

Dehumidifier Capacity

60 pts/day

Power

Cooling

1390W

Heating

1180W

Air Flow Volume

225CFM

Power Source

115 V~60 HZ

11 / 12.5 AMP

Heating / Cooling

Noise Level

46dB (A) 

Net Weight

88 lbs

Operating Temp

Cooling

60.8 

°

F - 107.6 

°

F

Heating

23 

°

F - 89.6 

°

F

Product Dimensions

17.7”×18.9”×31.7”

Refrigerant

R-410A

Содержание CR13000-PAC

Страница 1: ...ules and instructions before operating this equipment THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY Please keep this manual for future reference Portable Air Conditioner ClimateRight USA Questions o...

Страница 2: ...___ Date Purchased _________________________________________________ Serial Number located on back of unit ______________________________ IMPORTANT INSTRUCTIONS Before installing and using your portab...

Страница 3: ...ing recommendations WARNING 1 DO NOT press the TEST button while the air conditioner is operating 2 The TEST and RESET buttons should not be used as ON and OFF switches 3 The cord and plug are not int...

Страница 4: ...to properly fit the opening 7 Attached the window kit adapters to the window kit Close the window or door tightly Your Portable Air Conditioner is now ready to cool NOTE When using the venting system...

Страница 5: ...cover on the back of the unit and install the square air intake vent with removable washable filter For Single Hose Window Kit Installation To install the window kit follow the same directions on page...

Страница 6: ...ppears on the Multi color display 5 Press the or buttons until the desired room temperature appears on the control panel display The temperature ranges from 61 F 88 F 16 C 31 C 6 Select the desired fa...

Страница 7: ...when the compressor turns on The icon will turn off when the compressor shuts off Emergency Condensate Holding Tank When the room temperature is low and the indoor humidity is high the air conditioner...

Страница 8: ...illate up and down The bottom left square of the remote control display will show the icon when oscillation SWING is selected 7 TIMER To program the timer first press the T ON button Once T ON is pres...

Страница 9: ...over used salvaged or refurbished products As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above lim...

Отзывы: