OPTION SELECTION

TT026                                       S N - - - - - 1 2 3 4

TT026                                       S N - - - - - 5 6 7 8

TT038                                       S N - - - - - 9 0 1 2

 PREVIOUS                                        SELECT 

4.0  Accessory Confi guration

A service message will fl ash at the top of the Main screen 
when a service timer expires to alert the user that it is time to 
service these options. Refer to DXM2 AOM for instructions on 
confi guring DIP switches to confi gure accessories. Follow the 
instructions below to set service timers.

5.0  Input Dealer Information

Enter/edit the Dealer Information settings, including Brand 
Name, Model Number, Serial Number, Contractor Name, and 
Contractor Phone number, using the up/down arrow buttons.  
Press the center button to save changes.

4.1 AIR 

FILTER

This feature displays an alert to remind the user to change 
the air fi lter after the selected time has passed.

Adjust the Air Filter Reminder settings using the up/down 
arrow buttons.  Press the center button to save changes.
 

•  Cumulative Run Time (default Off) – 

valid range:  

 

 

Off, 400 to 3600 hours (in 100 hour increments

)

 

•  Calendar Time (default Off) – 

valid range:  Off, 3 

 

 

to 48 months (in 3 month increments)

4.2 HUMIDIFIER

This feature displays an alert to remind the user to change 
the humidifi er pad after the selected time has passed.

Adjust the Humidifi er Reminder settings using the up/down 
arrow buttons.  Press the center button to save changes.

 

•  Cumulative Run Time (default Off) 

– valid range:  

 

 

Off, 400 to 3600 hours (in 100 hour increments)

 

•  Calendar Time (default Off) 

– valid range:  Off, 3 

 

 

to 24 months (in 3 month increments)

 

4.3 UV 

LAMP

This feature displays an alert to remind the user to change 
the UV lamps after the selected time has passed.

Adjust the UV Lamp Reminder settings using the up/down 
arrow buttons.  Press the center button to save changes.
 

•  Cumulative Run Time (default Off) 

– valid range:  

 

 

Off, 400 to 3600 hours (in 100 hour increments)

 

•  Calendar Time (default Off)

 – valid range:  Off, 3 

 

 

to 48 months (in 3 month increments)

4.4 AIR 

CLEANER

This feature displays an alert to remind the user to clean the 
fi lter(s) after the selected time has passed.

Adjust the Air Cleaner Reminder settings using the up/down 
arrow buttons.  Press the center button to save changes.
 

•  Cumulative Run Time (default Off)

 – valid range:  

 

 

Off, 400 to 3600 hours (in 100 hour increments)

 

•  Calendar Time (default Off) – 

valid range:  Off, 3 

 

 

to 24 months (in 3 month increments)

3.6.2 

MULTI-UNIT OPTION SELECTION

In section 3.2, when an installer selects “Option Selection” 
from the System Confi guration menu, the installer may 
choose the unit to confi gure by the last 4 digits of its serial 
number from the following screen.

3.6.3 

Multi-Unit, Unit, Pump, & Valve Confi guration

To confi gure Unit, Pump, and Valve options in sections 3.3-
3.5, the thermostat must be connected to only one unit at a 
time.

BRAND NAME

CLIMATEMASTER

MODEL NUMBER

TTV038AGD01ALKS

SERIAL NUMBER

1234567890

CONTRACTOR NAME

MR GEOTHERMAL

CONTRACTOR PHONE

555-1234

 PREVIOUS                                          SAVE 

INSTALLER SETTINGS

THERMOSTAT CONFIG

SYSTEM CONFIG

ACCESSORY CONFIG

INPUT DEALER INFO

HUMIDITY CONFIG

TEMPERATURE CONTROL

DEMAND REDUCTION CNFG

SERVICE MODE

SETPOINT LIMITS

RESTORE DEFAULTS
DXM2                                                               3.3

ATC32U02                                                    C 1.0

SELECT OPTION   

 PREVIOUS

Содержание iGate ATC32U03

Страница 1: ...Access 6 2 2 Thermostat Configuration 6 3 0 System Configuration 7 3 1 Airflow Selection 7 3 2 Option Selection 7 3 3 Unit Configuration 8 3 4 Pump Configuration 8 3 5 Valve Configuration 9 3 6 Multi...

Страница 2: ...This page was intentionally left blank...

Страница 3: ...need not be leveled for proper operation and mark wall through 2 mounting holes 5 Drill two 3 16 in mounting holes in wall where marked Note Mounting holes on thermostat are designed to fit on a hori...

Страница 4: ...ontrol algorithm must be configured for Differential control to access the Differential settings by installer 1 1 2 HUMIDITY OFFSET If you find that the Humidity level displayed on the thermostat does...

Страница 5: ...erature at the time when Demo Mode is entered The unit will operate in heating or cooling based upon the following algorithm 1 3 3 EXITING DEMO MODE To exit demo mode remove power to the thermostat St...

Страница 6: ...onds while the thermostat is in OFF Mode 2 2 THERMOSTAT CONFIGURATION Upon initial power up the communicating thermostat will prompt the installer for the thermostat configuration settings Model numbe...

Страница 7: ...e center button to select each item Airflow Settings defaults stored in control valid range obtained from control in 25 CFM increments Blower Off Delay default 60 seconds valid range 0 to 255 seconds...

Страница 8: ...OP CONFIG VS PUMP SELECT OPTION PREVIOUS SAVE 3 4 PUMP CONFIGURATION vFlow vs internal flow control pump can be controlled either through temperature differential Delta T or can be set to specific spe...

Страница 9: ...figuration instructions MODULATING VALVE CONFIGURATION OFF POSITION 0 0 VALVE CONTROL DELTA T HEATING DELTA T 7 F COOLING DELTA T 10 F MAXIMUM HEAT LWT 80 F MINIMUM COOL LWT 40 F PREVIOUS SELECT For c...

Страница 10: ...ts Calendar Time default Off valid range Off 3 to 24 months in 3 month increments 4 3 UV LAMP This feature displays an alert to remind the user to change the UV lamps after the selected time has passe...

Страница 11: ...ershooting the temperature setpoint adjust the Anticipator value up to reduce thermostat sensitivity If the thermostat is undershooting the temperature setpoint adjust the Anticipator value down to in...

Страница 12: ...the center button to save changes Smart Heat Staging default Off options OFF 5 120 minutes in 5 minute increments 7 6 ELECTRIC HEAT LOCKOUT Electric heat lockout keeps electric heat turned off if the...

Страница 13: ...3 1 ON FACTORY SETTING 2 OFF HWG TEST OFF 3 OFF HWG SP 125 4 OFF HWG DISABLED JW3 LT1 SETTING WELL PREVIOUS 9 3 DIPSWITCH CONFIGURATION Dipswitch Configuration mode allows the service personnel to vie...

Страница 14: ...9 7 9 4 4 Configuration Conditions Displays the status of all dipswitch settings that were recorded at the time the fault occurred NOTE If multiple units are connected to one thermostat refer to secti...

Страница 15: ...onnected directly to the ATC thermostat or connected to one another in series as shown by the figure below CONTROL DIAGNOSTICS TT026 S N 1 2 3 4 TT026 S N 5 6 7 8 TT038 S N 9 0 1 2 PREVIOUS SELECT TT0...

Страница 16: ...imateMaster s opinion or commendation of its products ClimateMaster Inc 2012 97B0055N03 7300 S W 44th Street Oklahoma City OK 73179 Phone 405 745 6000 Fax 405 745 6058 climatemaster com Rev November 3...

Отзывы: