Flow Controller 3
R e v. : F e b u r a r y 9 , 2 0 1 6
A F C G 2 C 1
1 2 3
4
5
6
7
Accessory Flow Controller
1 = 1 Pump
# of Pumps
B = Brass 3-way valve with double O-ring fittings
Valves
Pump Model #
1 = UP26-99
2 = UP26-116 (AFC2B2 only)
3 = UPS32-160
4 = UPS60-150
Vendor/Series
G = Current Series
2 = 2 Pumps
C = Composite 3-way valve with double O-ring fittings
Rev.: 12/07/10
Model Nomenclature
GENERAL INFORMATION
Figure 1a: Flow Controller Dimensions (1 Piece Cabinet)
7.6” [192mm]
(includes pump)
10.2” [259mm]
13.5” [335mm]
5.0” [127mm]
4.7” [119mm]
4.7” [119mm] 4.7” [119mm]
4.7” [119mm]
Figure 1b: Flow Controller Dimensions (2 Piece Cabinet)
6.9” [174mm]
(includes pump)
10.2” [259mm]
14.9” [378mm]
5.0” [127mm]
4.5” [114mm]
4.5” [114mm] 4.5” [114mm]
4.5” [114mm]
FLOW CONTROLLER DESCRIPTION
The AFC series Flow Controller is a compact, easy to mount
polystyrene cabinet that contains 3-way valves and pump(s)
with connections for flushing, filling and pumping residential
geothermal closed loop systems. The proven design is foam-
insulated to prevent condensation. Full flow service valves
minimize pressure drop. One or two Grundfos pump models
UP26-99 or UP26-116 are available for a variety of unit flow
rates and loop layouts. Flow Controllers are designed for
systems that require water flow rate of up to 20 U.S. GPM
[1.26 l/s]. Unit and loop connections are designed for double
o-ring adaptor fittings for a variety of connection types
(fusion, threaded, barbed, cam). Pumps are 230VAC, 60Hz.
An attractive gray polystyrene cabinet with black pump(s)
provides an esthetically pleasing enclosure for pump(s) and
valves.
Safety
Warnings, cautions and notices appear throughout this
manual. Read these items carefully before attempting any
installation, service or troubleshooting of the equipment.
DANGER: Indicates an immediate hazardous situation, which
if not avoided will result in death or serious injury.
DANGER labels on unit access panels must be observed.
WARNING: Indicates a potentially hazardous situation, which
if not avoided could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation or an
unsafe practice, which if not avoided could result in minor or
moderate injury or product or property damage.
NOTICE: Notification of installation, operation or
maintenance information, which is important, but which is
not hazard-related.