Multi-Appliance Comfort Control
Controls- Installation / Setup / Commissioning
SETTING UP THE CONTROLS – DUAL CYCLE REFRIGERATIVE AIR CONDITIONING
The PNE control board in the Bonaire Central Heating units, has the option to run the room air fan in
continuous mode or cycling OFF / ON with the dual cycle refrigerative condenser unit.
S
ETTING THE
F
AN
C
ONTROL FROM
A
UTO TO
C
ONTINUOUS
M
ODE
S
ETTING
P
ROCEDURE
To alter the fan operation mode, you will need to change the screen display to reflect evaporative air
conditioning
COOL FRESH AIR
for a short period of time.
Step 1
Using the HEAT / COOL / FRESH AIR button set the unit operation to
COOL (
for dual cycle
refrigerative air conditioning) only.
Step 2
Press and hold down the HEAT / COOL / FRESH AIR and the ECONOMY / BOOST
BUTTONS for approximately 5 seconds and the screen display will change to
COOL FRESH
AIR.
Step 3
Setting the fan cycle mode
1.
Make sure the controller is in
MANUAL
mode
and is set to
COOL FRESH AIR
.
2.
Press the ENTER button and the MANUAL / AUTO
buttons together for 10 seconds pressing the
ENTER button first. The word
OPT
and some
numbers will flash on the screen.
3.
Using the
▼
or
▲
buttons make the top number
read
02
. Press ENTER
.
4.
Using the
▼
or
▲
buttons change the number of
the second line to
01
. Press ENTER.
The central heater fan is now set to “continuous operation” for the dual cycle refrigerative air
conditioning.
Step 4
Turn the controller
OFF
then
ON
again to transmit the new information to the heater control
board.
Step 5
Finally, you will need to change the screen back to
COOL
for dual cycle refrigerated air
conditioner mode. Ensure the screen displays COOL FRESH AIR.
Press and hold down the HEAT / COOL / FRESH AIR and the ECONOMY / BOOST
BUTTONS for approximately 5 seconds and the screen display will change to
COOL.
The central heater fan is now set to “continuous operation” for the dual cycle refrigerative air conditioning.
The room air fan will now run continuously and the condenser will cycle on and off.
As the add-on cooler is an add-on to your ducted gas central heater there are no further setup functions to
be completed.
Comfort Control - PNE
Page 41