56
© 2008 Directed Electronics. All rights reserved.
Shutdown diagnostics
To perform shutdown diagnostics:
With the ignition OFF, press and hold the Valet/Program switch.
1.
Turn the ignition ON and then back OFF while holding the Valet/Pro-
2.
gram switch.
Release the Valet/Program switch.
3.
Press and release the Valet/Program switch. The LED flashes a number of
4.
times on the control center to report the last shutdown for one minute or
until the ignition is turned on, as shown in the following table:
LED Flashes
Shutdown Mode
1
Runtime expired
2
Over-rev shutdown
3
Low or no RPM
4
Transmitter shutdown (or optional push button)
5
(+) Brake shutdown
6
(-) Hood shutdown
7
Timer mode/Turbo mode/Manual mode error *
8
Neutral safety shutdown
9
Low battery (voltage mode)
10
-------------------------------------------------------
11
Wait-to-start input timed out
*
Timer mode error: Ignition is on or shutdown input is active when activating
timer mode.
Turbo mode error: Turbo mode is programmed off, engine is not on or
shutdown input is active.
Manual mode error: MTS not enabled.