OPERATION CONDITIONS AND SAFETY PRECAUTIONS

Read all instructions carefully.

• All components need to be installed in accordance with the user 

manual instructions for correct performance of unit.

• This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a 
person responsible for their safety.

• Children should be supervised to ensure that they do not play 

with the appliance.

• A power outlet is required to operate the appliance. Electrical 

supply required  220~240V/50Hz.

• Ensure unit is properly grounded.

• To protect against fire, electric shock and personal injury, do 

not spray water onto the unit, do not immerse cord, plugs, or 
appliance in water or other liquid. Do not push any objects in the 
unit air inlet and air outlet exhaust grilles.

• Unplug from outlet when not in use and before cleaning. Never 

unplug unit with wet hands.

• Do not operate any appliance with a damaged cord or plug or after 

the appliance malfunctions, or has been damaged in any manner. 

• Return appliance to the nearest authorized service facility for 

examination, repair or adjustment.

• The use of accessory attachments not recommended by the 

appliance manufacturer may result in fire, electric shock or 
personal injury.

• Ventilation – The appliance air vents and exhaust grilles must 

not be obstructed at anytime. Air flow is required for the unit to 
operate effectively. Place unit in a flat well-ventilated location at 
least 30cm from wall or other appliances.

• Do not use outdoors.

• Do not use in wet environments e.g. Bathrooms or Showers.

• Do not let cord hang over edge of table or counter,  

or touch hot surfaces.

• Do not use appliance for other than intended use.

• This appliance should always be used in conjunction  

with a safety switch.

• Do not place the unit near an oven, heater, radiator, direct 

sunlight or any other heat source.

• Do not use unit near flammables or fire.

• Ensure unit is on a stable and even flat surface to prevent unit 

from falling or tipping over and to reduce possible excessive 
vibration and noise.

Содержание CLI-DH8D

Страница 1: ...CLI DH8D Installation Operating Instructions Air Dryer Dehumidifier ...

Страница 2: ...ampness Note Please read through the instructions carefully before using or installing the product and ensure that the manual is kept in a safe place for future reference The system must be properly installed and located in accordance with the installation instructions before it is used During the set up of this product if you have any questions comments issues DO NOT RETURN TO STORE For service a...

Страница 3: ...aced and operated on an angle as water spillage from reservoir can occur Empty the water when water reservoir is full or not in use for a prolonged period Recommended operating temperature range is minimum 5 degrees Celsius RH 41 and maximum 37 degrees Celsius RH 98 Any servicing other than cleaning and user maintenance will violate the terms of this WARRANTY and warranty will be null and void Not...

Страница 4: ... and before cleaning Never unplug unit with wet hands Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner Return appliance to the nearest authorized service facility for examination repair or adjustment The use of accessory attachments not recommended by the appliance manufacturer may result in fire electric shock or person...

Страница 5: ... s compressor range of dehumidifiers Classified as a desiccant dehumidifier there are key functions and benefits that set it apart from traditional dehumidifiers Traditional dehumidifiers lose their moisture absorbing effectiveness as the temperature drops They work well at higher temperatures above 20o C The Cli Mate Air Dryer Dehumidifier on the other hand is not affected by temperature and is a...

Страница 6: ...ous Drainage Outlet For hose connection E Water Reservoir F Power Cord G LED Monitor H Control Panel I Water Pane Continuous drainage hose is an extra drainage option hose does not need to be connected if using the water reservoir to catch condensed water A PARTS IDENTIFICATION DIAGRAM I E F G H A C D B ...

Страница 7: ...humidification setting is automatically set at continuous 2 To select the dehumidification mode press MODE button to select Quiet L normal M or fast H dehumidification respectively LED light will indicate current setting Note When fast dry H dehumidification mode is set humidity ratio setting cannot be set 3 To select room relative humidity RH ratio press HUMID button to select 40 50 60 respective...

Страница 8: ...ed and emptied before unit will operate again D PROTECTION OF INTERNAL OVER HEATING In the event the unit malfunctions and overheats due to air intake or air outlet being obstructed or blocked by foreign objects the unit will shut down automatically Unplug unit from wall socket and allow unit to cool down for a minimum of 5 minutes before operating the unit again Note The appliance air vents and a...

Страница 9: ...et External cleaning of unit Do not clean unit with any abrasive cleaning agents or solvents Do not apply any water directly to the unit of cleaning Only use a soft clean cloth for all cleaning purpose Cleaning Filter Remove Air Intake Grille below to access filter see Fig 3 Use a vacuum cleaner or wash in cool water to clean filter Allow to dry thoroughly before replacing filter and Air Intake Gr...

Страница 10: ...been reached 3 Air guide panel not open 4 Water Reservoir is full 1 Check connection to wall socket 2 Wait 30 minutes turn unit back on 3 Ensure there are no objects obstructing air guide panel from opening 4 Empty water reservoir Unit Overheating 1 Air ventilation around unit not sufficient 2 Air intake grille or air outlet is being obstructed or blocked by foreign objects 1 There must be at leas...

Страница 11: ...at base of unit 1 Water reservoir no installed correctly 2 Continuous drainage hose not connected to spigot properly 3 Continuous drainage hose outlet not over water drain 1 Reinstall water reservoir 2 Check hose connection 3 Check hose outlet is flowing into water drain Beeping Alarm noise 1 Water Reservoir is Full 1 Remove and empty water reservoir Customer care 1300 764 325 ...

Страница 12: ...tralian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure Conditions Of This Warranty 1 This product has been fully installed in accordance with the u...

Страница 13: ...INSTALLATION AND OPERATING INSTRUCTIONS 11 ...

Страница 14: ......

Страница 15: ......

Страница 16: ...HOTLINE 1300 764 325 Aquaport Corporation Pty Ltd PO Box 81 Findon SA 5023 Australia Telephone 08 8354 0711 Facsimile 08 8354 0722 climatebrand ClimateBrand Email aquaport aquaport com au Web www cli mate com au ...

Отзывы: