Cleveland SteamerGard System WT-90 Скачать руководство пользователя страница 4

Dimensions

 

SteamerGard™ Model WT-90:

 30-1/4" Wide x 6-1/4" Deep x 16-1/2" High 

SteamerGard™ Control Panel:

 9 -1/2" Wide x 3-1/2- Deep x 6-1/2" High 

SteamerGard™ Storage Tanks:

 

5 Gallon —16-1/2" Diameter x 15-1/4" High (cylindrical with top mount valve)  
10 Gallon —16" Diameter x 33" High (Cylindrical with bottom mount valve)  
         

NOTE:

  For extra capacity, additional tanks may be added. 

WARNING:

 Reduced performance or failure of the 

SteamerGard™

 system due to improper 

installation, improper maintenance, or improperly treated feed water is not covered under the 
manufacturers limited warranty. Specifically, use of the 

SteamerGard™

 system with water supplies 

exceeding 80°F, 80 psi, or 1200 ppm (mg/I) of TDS will void the manufacturers warranty. 

INSTALLATION INSTRUCTIONS 

1. 

Locate the 

SteamerGard™

 Model WT-90 on a wall, in a dry area, with access to a cold water supply 

(preferably softened) and a drain. The location should provide easy accessibility for future filter changes and 
service. On a level horizontal line, where the top of the unit is to be located, mark two points 11 3/16" apart. Drill a 
5/16" hole at each mark. Insert the anchors supplied and tap flush with wall. Remove the two screws securing the 
front of the

 SteamerGard™

 cover and remove the cover. Align the two mounting holes on the back plate of the 

unit chassis with the two anchors and affix the system in place with the two 10 X 1 1/2" SS screws. Replace the 

SteamerGard™

 Cover and secure with screws. Ensure that the unit is level. 

2. 

Locate the

 

storage tank

 in any convenient place between the 

SteamerGard™

 unit and the steamer. 

Generally, the storage tank is located near the

 SteamerGard™

 unit. The storage tank sets on the floor, and does 

not need to be secured to the floor. The storage tank should be within 50 feet of the steamer, unless the next 
larger size polybutytene tubing (1/2") is used. Screw the shut-off valve (supplied) onto the threaded connection of 
the storage tank, then screw the tee (supplied) onto the valve. 

3. Locat

e

 the control panel

 on a wall near the steamer and position it to be within reach and with access to a 

cold water supply. Carefully holding the control panel against the wall, mark the four mounting hole locations that 
will provide a level installation. Drill four 5/16" holes at the marks for mounting the panel. Insert the anchors 
supplied and tap flush with wall. Secure the control panel to the wall using four # l0 x 1-1/2" screws and washers 
into the four hollow wall anchors (or most appropriate method). Ensure that the control panel is level and adjust as 
required. 

4. Cold Tap Water Feed Line

 

to the

 

SteamerGard

 Unit:

 In accordanace with accepted plumbing methods, the

 

SteamerGard™

 unit should be plumbed from an existing cold water supply (3/8" minimum) using a tee and a 

shut-off valve. Run up to 25 feet of 3/8" tubing (1/2" tubing if longer than 25 feet) from the valve at the cold water 
supply (preferably softened) to the FEED WATER connection on the 

SteamerGard™

 unit. 

OPTIONAL

: Before connecting the feed water line to the 

SteamerGard™

 unit, the storage tank may be filled with 

tap water. Before tank is filled always check that air pre-charge is 7 psi. If the tank is not initially filled with water, it 
will take up to one hour for the 

SteamerGard™

 system to fill the tank with enough purified water to operate the 

steamer. If it is desirable to fill the tank, remove one of the plugs from one side of the tee on the shut-off valve of 
the tank, be sure the other side of the tee is plugged. Connect the feed water line to the unplugged compression 
fitting of the tee. Open the valve on the tank and open the cold tap water supply valve. Allow the tank to fill for 
approximately 30 seconds. Close both valves. Disconnect the feed water line from the tank. Move the tank to its 
permanent location. 

5. 

Drain Water Line:

 Run up to 25 feet of 3/8" tubing (1/2" tubing if longer than 25 feet) from the DRAIN 

connection of the

 SteamerGard™

 unit to the nearest drain. The

 SteamerGard™

 system has a pressurized drain 

and therefore, the drain tubing may be run up to 5 feet above the

 SteamerGard™

 unit. The drain termination 

must 

vent freely to the air, with a proper air gap between the tubing termination and the drain opening, in order to 
comply with local plumbing codes. 

 

2

 

Содержание SteamerGard System WT-90

Страница 1: ...nge Inc UNITED STATES 1333 East 179th St Cleveland Ohio 44110 Phone 216 481 4900 Telex 98 0546 FAX 216 481 3782 Toll Free 1 800 782 0040 in U S A only CANADA 8251 Keele St Concord Ontario Canada L4K 1...

Страница 2: ...el Illustrations 3 WT 90 System Component Illustrations 4 WT 90 Typical Installation Schematic 5 Use and Care Operation 6 SteamerGuard Remote Control Panel 6 Manual Bypass Valve 6 Tank Pressure Gauge...

Страница 3: ...ompression fittings for connection to the storage tank the steam generator and a tap water supply 3 8 OD polybutylene tubing is recommended for plumbing Storage Tank The storage tank is a self contain...

Страница 4: ...mer and position it to be within reach and with access to a cold water supply Carefully holding the control panel against the wall mark the four mounting hole locations that will provide a level insta...

Страница 5: ...ltered for use with the SteamerGard system Consult the steamer manufacturer for alteration instructions to convert the steamer from a single teed water connection to two separate water connections one...

Страница 6: ...e Fitting 1 4 11 45 2111931 10 Clear Filter Bowl 4 60 9011 RO Auto Shutoff Valve 12 47 1212419 5 Micron Prefilter 5 35 412 1 5 Clip Auto Shutoff Valve 13 47 211211 55 Cu In Carbon Prefilter 6 52 31678...

Страница 7: ...Steamergard Model WT 90 Typical Installation Schematic...

Страница 8: ...amerGard system to be bypassed providing untreated tap water to the steamer until repairs can be made To use the manual bypass valve turn the handle fully clockwise so that the handle points to the by...

Страница 9: ...er the steamer has been in use for a while This ensures that the SteamerGard system has been in operation producing purified water Every three months perform the following NOTE The SteamerGard unit mu...

Страница 10: ...n the post treatment bowl a The clear post treatment bowl allows for easy inspection of the post treatment cartridge without the need to remove the bowl If the level of cartridge material remaining is...

Отзывы: