SteamerGard™ Model WT-90

 

INSTALLATION SPECIFICATIONS

 

IMPORTANT NOTE:

 The SteamerGard™ system is designed to provide purified water for use in the 

steam generator (boiler) of the steamer 

only

.

 A separate tap water supply line is required for the 

condenser system of the steamer. It is the responsibility of the steamer owner or the installer to provide 
two separate water connections; one for purified water to the steam generator and a separate one for tap 
water to the condenser system. 

SteamerGard™ Components: 

SteamerGard™ Unit

 

The

 SteamerGard™

 unit is the heart of the system. It converts available tap water into chemically adjusted and 

purified water using a combination of modem water treatment technologies. The SteamerGard™ unit is designed 
to be wall mounted and should be positioned to provide easy access for future filter changes and servicing, along 
with access to a cold water supply (preferably softened) and an open drain. The

 SteamerGard™

 unit is equipped 

with three 3/8" compression fittings to connect to the feed water supply, drain, and storage tank. 3/8" OD 
polybutylene tubing is recommended for plumbing. 

Control Panel

 

The control panel is designed to give the operator important information about the status and performance of the 
SteamerGard™ system, as well as to provide a manual system bypass to revert the steamer to tap water 
operation should overuse or failure cause the storage tank to become depleted. The control panel is designed to 
be wall mounted in a convenient and accessible location in the vicinity of the steamer and with access to a cold 
tap water supply. It uses a standard 9 volt battery to power the WATER QUALITY MONITOR , so no special 
wiring is required. It is equipped with three 3/8" compression fittings for connection to the storage tank, the steam 
generator and a tap water supply. 3/8"OD polybutylene tubing is recommended for plumbing. 

Storage Tank

 

The storage tank is a self-contained unit, and requires no power. It provides storage and pressure of purified 
water for use in the steamer. The storage tank should be set on the floor anywhere between the

 SteamerGard™

 

unit and the steamer. The storage tank is fitted with either a 3/8" or a 1" shut-off valve, dependent on the size of 
the tank, and a 3/8" tee, for connection to the

 SteamerGard™

 unit and the steamer. 3/8" OD polybutylene tubing 

is recommended for plumbing.

 

Important:

 The Storage tank air precharge should be 7 psi with no water. 

Plumbing

 

The SteamerGard™ system is designed for operation with cold water (40°F - 80°F), at pressures of 40 - 80 psi, 
containing less than 1200 ppm (mg/l) of TDS. The SteamerGard™ system is designed to be plumbed with 3/8" 
OD polybutylene tubing. 3/8" plastic ferrules (sleeves) are supplied with the system and must be used when 
plumbing polybutylene tubing to brass compression fittings. (Note: The tapered end of the plastic ferrule fits into 
the fitting body.) If copper tubing must be used for the feed water supply line, be sure to use brass ferrules 
(sleeves). If the SteamerGard™ system installation requires unusually long plumbing runs, it may be necessary 
to increase the size of the tubing from 3/8" OD to 1/2" OD (refer to the installation instructions for details), and 
change certain 3/8" compression fittings to 1/2" compression x 1/4" MPT fittings. All manual water valves used in 
the SteamerGard™ system are open when the handle is parallel to the valve body, and are closed when the 
handle is perpendicular to the valve body. 3/8" OD polybutylene installation tubing is available from The Water 
Factory. For long plumbing runs, 1/2" OD polybutylene tubing is available, along with the required 1/2" 
compression x 1/4" MPT fittings. 

 

1

 

Содержание SteamerGard System WT-90

Страница 1: ...nge Inc UNITED STATES 1333 East 179th St Cleveland Ohio 44110 Phone 216 481 4900 Telex 98 0546 FAX 216 481 3782 Toll Free 1 800 782 0040 in U S A only CANADA 8251 Keele St Concord Ontario Canada L4K 1...

Страница 2: ...el Illustrations 3 WT 90 System Component Illustrations 4 WT 90 Typical Installation Schematic 5 Use and Care Operation 6 SteamerGuard Remote Control Panel 6 Manual Bypass Valve 6 Tank Pressure Gauge...

Страница 3: ...ompression fittings for connection to the storage tank the steam generator and a tap water supply 3 8 OD polybutylene tubing is recommended for plumbing Storage Tank The storage tank is a self contain...

Страница 4: ...mer and position it to be within reach and with access to a cold water supply Carefully holding the control panel against the wall mark the four mounting hole locations that will provide a level insta...

Страница 5: ...ltered for use with the SteamerGard system Consult the steamer manufacturer for alteration instructions to convert the steamer from a single teed water connection to two separate water connections one...

Страница 6: ...e Fitting 1 4 11 45 2111931 10 Clear Filter Bowl 4 60 9011 RO Auto Shutoff Valve 12 47 1212419 5 Micron Prefilter 5 35 412 1 5 Clip Auto Shutoff Valve 13 47 211211 55 Cu In Carbon Prefilter 6 52 31678...

Страница 7: ...Steamergard Model WT 90 Typical Installation Schematic...

Страница 8: ...amerGard system to be bypassed providing untreated tap water to the steamer until repairs can be made To use the manual bypass valve turn the handle fully clockwise so that the handle points to the by...

Страница 9: ...er the steamer has been in use for a while This ensures that the SteamerGard system has been in operation producing purified water Every three months perform the following NOTE The SteamerGard unit mu...

Страница 10: ...n the post treatment bowl a The clear post treatment bowl allows for easy inspection of the post treatment cartridge without the need to remove the bowl If the level of cartridge material remaining is...

Отзывы: