22
SAFETY THERMOSTAT:
✘
Probe
removed
partially
✘
Probe
removed
completely
✘
Thermostat
electrically
bypassed
✔
Probe
fully
inserted
in tube
Wiring is properly
connected
1
2
3
Incorrect
Installations
1
Safety thermostat
probe is not
completely
inserted into
tubing.
2
Safety thermostat
probe is removed
from tubing.
3
Safety thermostat
electrical
connection is
bypassed.
Low Water Level Probe:
Probe bypassed by
running (A) an
additional wire
Probe properly
attached
260º - 270º
MAXIMUM
KETTLE
TEMPERATURE
265º
✔
If maximum temperature
is not in this range (on
empty kettle), refer to the
CALIBRATING
PROCEDURE on
page #29.
Operating
Thermostat:
✔
✘
Probe bypassed by
(B) grounding the
connecting wire
✘
(A)
(B)
✘
Switch
electrically
bypassed
✔
Wiring is
properly
connected
Air
Switch:
Incorrect
Installation