RECOMMENDED PLUMBING

 (continued): 

Stand Pipe: A vertical pipe holding a column of water, topped with a column of air. The air pocket provides a "shock absorber" 
effect, to reduce or eliminate the possibility of "water hammering" in the plumbing. 
Strainer Removes particles from the water supply which could result in damage to plumbing components. 

 Pressure Reducing Valve: Required if the incoming water pressure exceeds 60 psi. 

Check Valve: Eliminates the possibility of steam generafor water backing up into the water supply plumbing. (This check valve  

                                 may be required by local plumbing codes.) 

WATER QUALITY REQUIREMENTS

 

If the purity of the incoming water is good, the generafor, the heating element and the valves should give years of trouble free. efficient 
service with a minimum of servicing. 

The recommended minimum water quality standards, whether untreated or pretreated, based upon 4 hours of operation before the steamer is 
shut off and allowed to drain, are

 

as follows: 

• TOTAL DISSOLVED 

less than 60 parts per million 

•SILICA 

less than 13 parts per million 

• TOTAL ALKALINITY 

less than 20 parts per million 

• pH FACFOR 

greater than 7.5 

 

Consult a local water treatment specialist for an on-the-premises water analysis and for recommendations concerning steam 
generafor

 feed

 water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of a 

poor quality (highly mineralized) water will mean that more frequent servicing of water sensitive components will be 
necessary. The fact that a water supply is potable is not proof enough that it will not be detrimental to the water sensitive 
components. The steamer should be shut off for 3 minutes every 4 hours, in order to minimize scale build-up.

 

DRAIN

 

A 1" N.P.T. fitting is provided. The drain termination must be free venting. Up to two elbows and a maximum of six feet of I* I-
P.S. pipe may be attached to the termination. However, the piping must have a gravity flow and vent freely to the air. Each steamer 
requires its own 1" I.RS. drain extension. Do not interconnect any other drains to this steamer's drain extension. 

If these instructions

 are

 nor 

complied with, there will be steam and water leakage past 

the compartment door.

 

INSTALLATION CHECK

 

Installer must check out the steamer per the following procedure.

 

 

CHECK OUT STEPS 

1) Empty the cooking chamber of all literature and

 

leave the door open. 

2) Make sure the cold water supply line to the generafor is open. 
3) Turn on the electrical service to the cooker at the fusible disconnect box. 
4) Push the "water on" switch button to the right. The switch is illuminated when it is in the "ON" position. 
5) Set the steam control at number ten. Steam should be visible inside the cooking chamber after five minutes of operation. 
6) Let the steamer continue to operate for five additional minutes with the steam control set at ten. Steam flow should be visible for      

                this entire period of operation. 

7) Set the steam control to number five. Steam will continue to flow but in a lesser amount. 
8) To check the timer and buzzer, turn the timer past 10 minutes to wind it. Then reset the timer at three minutes. At the end of the         
    three minutes, the buzzer will sound for three seconds and then stop. 

9) To completely shut down the steamer, push the "water on" switch button to the left (the light should go out), and turn the steam 

control knob to zero. The steam generafor water will automatically drain out. At this time. the generafor flush cycle will be 
energized. This system automatically flushes the generafor and drain line to assist in removal of lime deposits. After 3 minutes, 
the flush cycle should end and the steamer should shut off completely. 

     If the cooker has functioned

 

as described, it is ready for use. 

Installer:

 Please complete and mail the 

Insialler's Checklist. 

 

NOTE: 

The outer shell must

 be 

installed in place 

before proceeding.

 

Ref.

 

No.

 

Part No.

 

Description

 

1

 

SB110

 

Door handle

 

2

 

43905

 

Timer

 

3

 

40728

 

Steam— control

 

4

 

19993

 

On/Off power switch

 

5

 

20602

 

PIastic dnp trough

 

 

Содержание CET-5

Страница 1: ...Steamcraft II COUNTER TYPE CONVECTION STEAMER SERVICE MANUAL Model CET5 Printed 02 90...

Страница 2: ...standards tor manufacturers including UL A G A NSF ASME NB Bd CSA CGA ETL and others BOILER Steam Generator MAINTENANCE IS THE RESPONSIBILITY OF THE OWNER USER AND IS NOT COVERED BY THIS WARRANTY The...

Страница 3: ...to controls on the console Use a damp cloth for cleaning 4 Always leave the compartment door ajar when the compartment is not in use 5 Shut the unit down at the end of each day s operation as follows...

Страница 4: ...vely in specific models when more than one model is covered on the page are when necessary tor clarity depicted within circles on the illustration page How To Use The Parts Drawing From the illustrati...

Страница 5: ...Cleveland Steamcraft INSTALLATION INSTRUCTIONS II TM...

Страница 6: ...2 Install the four leveling pads or optional four legs into the threaded holes on the bottom of the steamer 3 Omit this next step if optional 4 legs are supplied Install the adjustable counter seal o...

Страница 7: ...mer s rating label The copper wiring must be adequate to carry the required current at the rated voltage Locate the terminal block cover and knock out plug at the upper left corner of the steamer s ba...

Страница 8: ...nation However the piping must have a gravity flow and vent freely to the air Each steamer requires its own 1 I RS drain extension Do not interconnect any other drains to this steamer s drain extensio...

Страница 9: ...op buzzing automatically 5 Remove the food from the cooking compartment promptly or it will continue cooking Steam flow is not shut off by the timer Steam flow is only shut off when the steam control...

Страница 10: ...or three minutes every 4 hours this purge system should provide a maintenance free steam generator However if your water contains more than 200partsper million of total dissolved solids additional mai...

Страница 11: ...16 18 Lima Beans Baby 5 1 12x20x2 1 2 5 2 3 12 Lima Beans Regular 5 1 12x20x2 1 2 8 2 3 14 Corn Lima Beans 50 1 2 3 12x20x2 1 2 6 8 17 18 Green Beans Carrots Variety Vegetables 4 1 12x20x2 1 2 4 Ital...

Страница 12: ...iladas 2 3 12x20x2 1 2 50 60 MEAT Beef Ground Chuck 10 1 12x20x2 1 2 33 Beef Cubes as purchased 10 1 12x20x2 1 2 40 45 Meat Loaf 4 Loaves 4 lb ea 16 1 12x20x2 1 2 40 42 Hotdogs Weiners 10 1 12x20x1 3...

Страница 13: ...Spring 11 40589 Latch Pin Retainer 2 required 12 02624 Bushing 13 40588 Hinge Pin Retainer 2 required 14 58198 Hinge 15 41423 Slide Assembly 16 62201 Strike 17 41101 Drain Screen used on units built b...

Страница 14: ...r 75 VA 7 43905 Timer With Knob 8 43956 Panel Assembly 9 16609 1 Brass Plug 10 40462 Probe Single 11 62459 Probe Extension 12 02626 Adaptor Bushing 13 41350 Buzzer 14 43908 Terminal Block 15 03518 Con...

Страница 15: ...14908 Label Control Panel not shown 8 20477 Timer Solid State 3 Second Buzzer 9 20478 Timer Solid State 3 Minute Water Flush 10 41350 Buzzer 11 03518 Contactor 4 Pole 30 AMP 12 43908 Terminal Block 13...

Страница 16: ...PSI 3 06188 Tee Tube Fitting 4 03350 Water Conditioner 5 22218 Valve Water Solenoid 6 15463 Flow Regulator 1 4 GPM 7 20245 Tee Male Branch 8 19880 Strainer 9 22217 Valve Drain Solenoid 10 16478 Drain...

Страница 17: ...03350 Water Conditioner 5 22218 Valve Water Solenoid 6 15463 Flow Regulator 1 4 GPM 7 06196 3 8Tee x 4 MPT 90 Compression Fitting 8 06214 1 4Tee x MPT 90degree Compression Pitting 9 19880 Strainer 10...

Страница 18: ...erator 12 22221 Valve Drain Special Solenoid 13 14551 Nozzle Jet Generator Drain 14 20247 1 2 Mate Run Tee 15 14554 Nozzle Jet Generator Drain 16 06192 1 4 Tube x 1 8 MPT 90 Compression Fitting 17 198...

Страница 19: ......

Страница 20: ......

Страница 21: ...STEAMCRAFT II 208V 220 240V ONLY WIRING DIAGRAM...

Страница 22: ...chemical plus a specially formulated blend of a corrosion inhibitor wetting agent and color change pH indicator to improve cleaning effectiveness in removing hard water scales and other deposits This...

Страница 23: ...n stand for several hours The descaling process can range in time from a few hours to overnight depending upon the severity of the scale When the descaling process is complete push the steamer s power...

Страница 24: ...The red light will illuminate when the steamer is on Turn the steam control knob to number 10 Leave the cooking compartment door open Steam should begin to appear inside the cooking compartment after...

Страница 25: ...3 PRODUCING NO STEAM CONTACTOR DOES ENERGIZE 2 Broken or burned wire connections between element and contactor 3 Contacts not making good contact in contactor 1 Steam control not turned on 2 Faulty s...

Страница 26: ...20 volts is measured across LI L2 on the level control board and no voltage is measured from L2 to WF on the level board 1 Faulty level control board 2 Check for grounded probe C If 120 volts is measu...

Страница 27: ...ger from seating thus allowing water to continually enter the generator through one of the solenoids II If 120 volts is measured across the purge solenoid coil A Purge timer contacts are stuck closed...

Страница 28: ...ohms at 208 volts 36 ohms at 240 volts 48 ohms at 480 volts 2 Steam control switch set too low 3 Excessive scale buildup on element reducing heat transfer to generator water 4 Supply voltage not corr...

Страница 29: ...in generator c Faulty level control board d Shorted wiring to ground from probe connections e Probe chamber scaled shut See drawing below If this area becomes blocked from scale buildup false water l...

Страница 30: ...This is usually caused by the steam control switch 11 CONTROL CIRCUIT PUSES These fuses control only the control ON BACK OF STEAMER circuit components CONTINUALLY BLOW 1 Shorted wiring in control cir...

Страница 31: ...g element 5 Carbon buildup across contactor contacts or heating element terminals AS A RULE OF THUMB IF A CIRCUIT BREAKER TRIPS IMMEDIATELY THERE IS A SHORT CIRCUIT IF IT STAYS ON A WHILE AND TEEN TRI...

Страница 32: ...switch is on steam switch is on a Normal operation condenser water is fed into drain line to condense steam so only condensate exits the drain line 15 STEAM LEAKS OUT OF COOKING COMPARTMENT DOOR 1 Th...

Страница 33: ...L NOT TIME OUT 1 Faulty timer replace 17 TIMER TIMES OUT BUT BUZZER 1 No voltage to buzzer WILL NOT SOUND a Timer contacts b Solid State Delay Timer 2 120 volts to buzzer a Inoperative buzzer replace...

Отзывы: