• With the steamer off, open the cooking compartment door and allow the steamer to cool before cleaning the cooking 

compartment and its components. 

2. The steamer is equipped with a drain screen in the back of the cooking compartment. The steamer should never be 

operated without the screen in place. This screen prevents large food particles from entering and possibly restricting the 
drain line. Any restriction of the drain line may cause a slight build-up of back pressure in the compartment, resulting in 
steam leaks around the door gasket. It also may adversely affect the convection action of the steam in the compartment, 
which is necessary for optimum performance. Pouring USDA approved drain cleaner through the compartment drain once a 
week will help to ens ure an open drain. 

3. At the end of each day's operation, remove any spilled food from the steamer, then wash the pan slide racks, drain screen, 

door gasket, and compartment interior with mild detergent and warm water. Rinse thoroughly with clear water. Rinse water 
should drain freely through the compartment drain opening. If it does not the drain must be cleaned before using the 
steamer. 

4. The pan slide racks are easily removed from the cooking compartment for  thorough cleaning, and they are stainless steel, 

so they can be washed safely in a mechanical dishwasher. 

5. Always leave the compartment door ajar when not in use, to extend gasket life and to prevent the gasket from adhering to 

the steamer. Unnecessary compression of the gasket shortens its life. 

6. Exterior Care: Allow steamer to cool before washing. Use the same cleaners and cleaning procedures as for other kitchen 

surfaces of stainless steel and aluminum. Mild. soapy water, with a clear water rinse, is recommended. Do not allow water to 
run into electrical controls. Always turn off equipment power before using water to wash equipment. Do not hose down the 
steamer. 

7. Once every three months, shut off the cold water supply to the steamer, and clean the water line strainer. 

MAINTENANCE

 

Your Steamcraft II is equipped with an automatic 3 minute water purge system which will flush the highly mineralized water out 
of the steam generator when the steamer is shut off. If the steamer's feedwater supply is of average hardness and mineral 
content (less than 200 parts per million of total dissolved solids), and the steamer is shut off for three minutes every 4 hours, 
this purge system should provide a maintenance free steam generator. However, if your water contains more than 200 parts per 
million of total dis solved solids, additional maintenance may be required. In this case. your steamer should be shut off every 2 
or 3 hours, depending upon the mineral content of the water. In addition, it may be necessary to periodically have a service 
technician remove the steam generator's side panel and clean the scale accumulations on the inside. 
The Cleveland Range Company supports a worldwide network of Maintenance and Repair Centers, which are regional 
distributors of parts and service. Contact your nearest Maintenance and Repair Center for the name of an authorized service 
agency in your area, or for replacement parts, or information regarding the proper maintenance and repair of your equipment. In 
order to preserve the various agency safety certifications (UL. A.G.A, CSA, CGA. NSF, ASME/Ntl. Bd, etc.), only factory-
supplied replacement parts should be used. The use of other than factory-supplied replacement parts will void the warranty.  

INSTALLATION CHECK

 

Proper operation of the Cleveland Steamcraft II is dependent upon proper installation. After the steamer has been installed, a 
few quick checks could save unnecessary service calls. 

1. The Steamcraft II requires a cold water connection at the rear of the steamer for proper efficient operation. DO NOT USE 

HOT WATER. The cold water feed line should maintain 35 to 60 psi flow pressure, and not experience a pressure drop when 
other appliances are used. Pressure in excess of 60 psi must be reduced (with a pressure reducing valve) to  35 to 60 psi. 

2. The steamer must be level. 
3. The supply voltage must agree with the voltage indicated on the rating label on the back of the steamer, and the voltage 

shown on the packing slip. The steamer must

 be

 protected with a separate fused disconnect and be property grounded, in 

accordance with the national electric code. 

4. The termination of the drain extension

 must

 vent freely to the air (not plumbed solidly into the floor drain). It must have a 

gravity flow, be 1" diameter minimum (IPS) and not exceed 6' in length, with no more than two elbows, before draining. Each 
steamer requires its own 1" IPS drain extension. Do not interconnect any other drains to this steamer's drain extension. 

CAUTION: IF THESE INSTRUCTIONS ARE NOT COMPLIED WITH. THERE WILL BE STEAM AND WATER LEAKAGE PAST THE 
COMPARTMENT DOOR GASKET.

 

260-SO(R1| 0485      __________________________________________________________________________________ 

Содержание CET-5

Страница 1: ...Steamcraft II COUNTER TYPE CONVECTION STEAMER SERVICE MANUAL Model CET5 Printed 02 90...

Страница 2: ...standards tor manufacturers including UL A G A NSF ASME NB Bd CSA CGA ETL and others BOILER Steam Generator MAINTENANCE IS THE RESPONSIBILITY OF THE OWNER USER AND IS NOT COVERED BY THIS WARRANTY The...

Страница 3: ...to controls on the console Use a damp cloth for cleaning 4 Always leave the compartment door ajar when the compartment is not in use 5 Shut the unit down at the end of each day s operation as follows...

Страница 4: ...vely in specific models when more than one model is covered on the page are when necessary tor clarity depicted within circles on the illustration page How To Use The Parts Drawing From the illustrati...

Страница 5: ...Cleveland Steamcraft INSTALLATION INSTRUCTIONS II TM...

Страница 6: ...2 Install the four leveling pads or optional four legs into the threaded holes on the bottom of the steamer 3 Omit this next step if optional 4 legs are supplied Install the adjustable counter seal o...

Страница 7: ...mer s rating label The copper wiring must be adequate to carry the required current at the rated voltage Locate the terminal block cover and knock out plug at the upper left corner of the steamer s ba...

Страница 8: ...nation However the piping must have a gravity flow and vent freely to the air Each steamer requires its own 1 I RS drain extension Do not interconnect any other drains to this steamer s drain extensio...

Страница 9: ...op buzzing automatically 5 Remove the food from the cooking compartment promptly or it will continue cooking Steam flow is not shut off by the timer Steam flow is only shut off when the steam control...

Страница 10: ...or three minutes every 4 hours this purge system should provide a maintenance free steam generator However if your water contains more than 200partsper million of total dissolved solids additional mai...

Страница 11: ...16 18 Lima Beans Baby 5 1 12x20x2 1 2 5 2 3 12 Lima Beans Regular 5 1 12x20x2 1 2 8 2 3 14 Corn Lima Beans 50 1 2 3 12x20x2 1 2 6 8 17 18 Green Beans Carrots Variety Vegetables 4 1 12x20x2 1 2 4 Ital...

Страница 12: ...iladas 2 3 12x20x2 1 2 50 60 MEAT Beef Ground Chuck 10 1 12x20x2 1 2 33 Beef Cubes as purchased 10 1 12x20x2 1 2 40 45 Meat Loaf 4 Loaves 4 lb ea 16 1 12x20x2 1 2 40 42 Hotdogs Weiners 10 1 12x20x1 3...

Страница 13: ...Spring 11 40589 Latch Pin Retainer 2 required 12 02624 Bushing 13 40588 Hinge Pin Retainer 2 required 14 58198 Hinge 15 41423 Slide Assembly 16 62201 Strike 17 41101 Drain Screen used on units built b...

Страница 14: ...r 75 VA 7 43905 Timer With Knob 8 43956 Panel Assembly 9 16609 1 Brass Plug 10 40462 Probe Single 11 62459 Probe Extension 12 02626 Adaptor Bushing 13 41350 Buzzer 14 43908 Terminal Block 15 03518 Con...

Страница 15: ...14908 Label Control Panel not shown 8 20477 Timer Solid State 3 Second Buzzer 9 20478 Timer Solid State 3 Minute Water Flush 10 41350 Buzzer 11 03518 Contactor 4 Pole 30 AMP 12 43908 Terminal Block 13...

Страница 16: ...PSI 3 06188 Tee Tube Fitting 4 03350 Water Conditioner 5 22218 Valve Water Solenoid 6 15463 Flow Regulator 1 4 GPM 7 20245 Tee Male Branch 8 19880 Strainer 9 22217 Valve Drain Solenoid 10 16478 Drain...

Страница 17: ...03350 Water Conditioner 5 22218 Valve Water Solenoid 6 15463 Flow Regulator 1 4 GPM 7 06196 3 8Tee x 4 MPT 90 Compression Fitting 8 06214 1 4Tee x MPT 90degree Compression Pitting 9 19880 Strainer 10...

Страница 18: ...erator 12 22221 Valve Drain Special Solenoid 13 14551 Nozzle Jet Generator Drain 14 20247 1 2 Mate Run Tee 15 14554 Nozzle Jet Generator Drain 16 06192 1 4 Tube x 1 8 MPT 90 Compression Fitting 17 198...

Страница 19: ......

Страница 20: ......

Страница 21: ...STEAMCRAFT II 208V 220 240V ONLY WIRING DIAGRAM...

Страница 22: ...chemical plus a specially formulated blend of a corrosion inhibitor wetting agent and color change pH indicator to improve cleaning effectiveness in removing hard water scales and other deposits This...

Страница 23: ...n stand for several hours The descaling process can range in time from a few hours to overnight depending upon the severity of the scale When the descaling process is complete push the steamer s power...

Страница 24: ...The red light will illuminate when the steamer is on Turn the steam control knob to number 10 Leave the cooking compartment door open Steam should begin to appear inside the cooking compartment after...

Страница 25: ...3 PRODUCING NO STEAM CONTACTOR DOES ENERGIZE 2 Broken or burned wire connections between element and contactor 3 Contacts not making good contact in contactor 1 Steam control not turned on 2 Faulty s...

Страница 26: ...20 volts is measured across LI L2 on the level control board and no voltage is measured from L2 to WF on the level board 1 Faulty level control board 2 Check for grounded probe C If 120 volts is measu...

Страница 27: ...ger from seating thus allowing water to continually enter the generator through one of the solenoids II If 120 volts is measured across the purge solenoid coil A Purge timer contacts are stuck closed...

Страница 28: ...ohms at 208 volts 36 ohms at 240 volts 48 ohms at 480 volts 2 Steam control switch set too low 3 Excessive scale buildup on element reducing heat transfer to generator water 4 Supply voltage not corr...

Страница 29: ...in generator c Faulty level control board d Shorted wiring to ground from probe connections e Probe chamber scaled shut See drawing below If this area becomes blocked from scale buildup false water l...

Страница 30: ...This is usually caused by the steam control switch 11 CONTROL CIRCUIT PUSES These fuses control only the control ON BACK OF STEAMER circuit components CONTINUALLY BLOW 1 Shorted wiring in control cir...

Страница 31: ...g element 5 Carbon buildup across contactor contacts or heating element terminals AS A RULE OF THUMB IF A CIRCUIT BREAKER TRIPS IMMEDIATELY THERE IS A SHORT CIRCUIT IF IT STAYS ON A WHILE AND TEEN TRI...

Страница 32: ...switch is on steam switch is on a Normal operation condenser water is fed into drain line to condense steam so only condensate exits the drain line 15 STEAM LEAKS OUT OF COOKING COMPARTMENT DOOR 1 Th...

Страница 33: ...L NOT TIME OUT 1 Faulty timer replace 17 TIMER TIMES OUT BUT BUZZER 1 No voltage to buzzer WILL NOT SOUND a Timer contacts b Solid State Delay Timer 2 120 volts to buzzer a Inoperative buzzer replace...