PROBLEM
POSSIBLE CAUSE
REMEDY/REFERENCE
ON/OFF Indicator on
but steamer does not
make steam in timed
mode
Timer fuse has blown (electronic timer
models only)
See note #1
Inoperative timer control or damaged
wiring
See note #1
Water is flowing out of
the steam ports into the
cooking compartment
Water level probes are dirty and are
not sensing properly
Turn OFF the water supply to the
steamer and descale the unit manually
with Cleveland Range approved
descaler by filling the unit with descaler
and water through the descaling port. If
condition persists, see note #1.
Inoperative timer control or damaged
wiring
See note #1
Water comes out of
descale port
Descale cap is missing
Install the descale cap. Descale port
must be closed tightly for the steamer to
operate properly. If missing, see note #8
Descale cap is loose
Tighten the descale cap. The descale
port must be closed tightly for the
steamer to operate properly.
Descale cap and/or gasket is
damaged.
See note #8.
Steam and/or water
issuing from small
valve at the top of each
steam generator
Steam generator scale buildup.
Descale steam generator with Cleveland
Range approved descaler. If condition
persists, see note #1.
Inoperative control
See note #1
TROUBLESHOOTING NOTES
1.
If problem is inside the steamer, call an authorized service representative. Cleveland Range
will not pay for warranty repairs by unauthorized repair centers.
2.
Proper installation of the steamer is the responsibility of the owner or installer. A qualified
installer or technician should be contacted to correct the installation. Refer to Cleveland Range
Warranty.
3.
Repairs to external plumbing should be done by a Licensed Plumber.
4.
Repairs to external wiring should be done by a Licensed Electrician.
5.
For more information on products and services, contact your nearest Authorized Sales
Representative. Call factory for a preventative maintenance program, descaling kits, descaling
information, and water treatment systems: USA: (800) 338-2204, Canada: (800) 427-6668.
6.
To evaluate whether a Gemini steamer is producing normal cooking performance, conduct
the Egg Test as follows (NOTE: this test is not valid for pressure steamers). A properly
operating steamer will produce cooked eggs as follows.
Turn on the steamer and set the selector switch to the manual mode (or for ON/OFF models
set the selector to the ON position) so that steam is being produced. When wisps of steam
have begun to exit the steam vent, preheat the steamer by leaving it ON for ten minutes.
After the compartment is preheated follow the instructions as listed below.
(Continued on next page)
TROUBLESHOOTING NOTES (Continued)