ATTEMPTING TO REPAIR OR CORRECT PROBLEMS REQUIRING A QUALIFIED
CLEVELAND RANGE AUTHORIZED SERVICE REPRESENTATIVE VOIDS THE WARRANTY
Table 6-1 Troubleshooting Guide
PROBLEM
POSSIBLE CAUSE
REMEDY/REFERENCE
Power indicator light
does not turn ON when
ON/OFF lever/switch is
in the ON position.
Power turned OFF at main external
power switch or breaker
Turn ON power at main external power
switch or breaker
ON/OFF lever/switch not fully turned to
the ON position.
Turn lever/switch to the full-ON position.
Inoperative controls or failed light.
See note #1
Power ON and steam
generator does not fill.
Water supply to steamer shut OFF.
Open water supply valves.
Water line strainer and/or external filter
system is clogged
Clean water supply strainer and/or filter
system.
Inoperative Solenoids or controls.
See note # 1.
Control panel POWER
indicator light ON and
steamer does not make
any steam in MANUAL
or TIMED mode.
Water supply to steamer shut OFF.
Open water supply valves.
Gas Supply turned OFF
Turn ON gas supply
Door interlock switch not engaged or
has failed.
Close door completely. If problem
persists, see note #1.
Water line strainer and/or external filter
system is clogged
Clean water supply strainer and/or filter
system.
Hi-limit switch has tripped.
See note #1.
Inoperative controls or solenoid.
See note #1.
Abnormal amount of
steam coming from
drain.
Water supply to condenser turned
OFF.
Open water supply valve.
Hot water instead of cold water
connected to condenser fitting.
See note #2.
Condenser water line strainer is
clogged.
Clean out condenser water supply
strainer. See note #1.
Condenser is clogged.
See note #1
Water supply line to the condenser
blocked, broken, or leaking.
Repair or replace water supply line. See
note #3.
Inoperative controls or solenoids.
Turn OFF electricity at main external
power switch. See note #1.
Abnormal amount of
steam coming from
drain during blowdown
cycle.
ON/OFF lever/switch is not turned fully
to the OFF position.
Turn ON/OFF lever/switch to the full
OFF position to start the proper
blowdown operation.
Reduced steam flow
into cooking
compartment.
Steam generator scale buildup
Descale steam generator with Cleveland
Range approved descaler.
Inoperative or improperly adjusted
controls
See note #1.