0
troUBle shootInG
Type of Malfunction / Cause
Possible Cause
Possible Clearance
x
Air system does not function
x
Check you have an electricity supply?
Malfunction in electrical mains
Are the plug connections to the
control correctly seated?
x
Control does not react
x
Control defective
x
Control element defective
x
Blower defective
Call electrician
Pull and reinsert plug
x
Reconfigure Poolmaster
x
Replace control
x
Replace control element
x
Replace blower
x
Hydro system function insufficient
x
Hydro system does not function
x
Filter at intake socket is blocked
x
Nozzle dirty
x
Is voltage applied?
Malfunction in electrical mains
Are the plug connections to the
control correctly seated?
x
Is the water level high enough?
x
Water level sensor does not react
x
Control does not react
x
Control defective
x
Control element defective
x
Hydraulic pump defective
x
Remove cover at intake socket and
clean filter (see service)
x
Clean nozzle (see service)
Call electrician
Pull and reinsert plug
x
Continue to fill tub
x
Adjust sensor
x
Replace sensor
x
Reconfigure Poolmaster
x
Replace control
x
Replace control element
x
Replace hydraulic pump
x
System switches itself on without an
obvious reason
x
Automatic cleaning function of the air
nozzles
x
Has the room temperature changed
(e.g. floor heating underneath the
whirlpool)
x
Has the humidity in the room changed
(e.g. use of a shower in the same room)
x
Were cables, water pipes or other
electrically conductive materials laid in
the area of the water level sensor?
x
Is/was cleaning work performed near
the tub? (e.g. moist cleaning cloth near
the water level sensors)
x
Okay
x
Readjust sensitivity of the water level
sensor
x
Readjust sensitivity of the water level
sensor
x
Reposition cables, water pipes or similar
x
Remove objects from the tub
x
Water nozzle
x
Nozzle dirty
x
Nozzle head not adjustable
is seized
is loose
x
Clean nozzle (see service)
Reposition O-ring behind head
Replace O-ring behind head
Leakage:
x
air
x
Water underneath the tub
x
Air hose loosened on:
Blower
Air distributor
Air nozzle
x
Hydro hose loose on:
Pump
Hydro nozzles
x
Drain/overflow defective?
x
Seals on nozzles leaking?
x
Acrylic material damaged?
x
Tub inflow connection leaking?
x
Tighten hose clamp / disconnect and
reconnect hose
x
Retighten hose clamp
x
Replace seals
x
Replace seals
x
Repair acrylic material with repair sets
x
Replace seals
x
Underwater lighting does not switch on
x
Is the water level high enough?
x
Lighting element defective?
x
Is voltage applied?
Malfunction in electrical mains
Are the plug connections to the
control correctly seated?
x
Water level sensor does not react
x
Continue to fill tub
x
Replace lighting element
Call electrician
Pull and reinsert plug
x
Adjust sensor
x
Replace sensor
Disinfektion:
x
Can not be started
x
Switches off during the process
x
Is the water level high enough?
x
Is the water level high enough?
x
Is the disinfectant container adequately
filled?
x
Continue to fill tub
x
Continue to fill tub
x
Replenish container with disinfectant.
English
Содержание 22804 Series
Страница 11: ...11 Deutsch English Nederlands...
Страница 13: ...13 1 2 Pos Pos X Y Z X Y Z Deutsch English Nederlands...
Страница 15: ...15 1 2 Pos Pos X Y Z X Y Z Deutsch English Nederlands...
Страница 17: ...17 1 2 Pos Pos X Y Z X Y Z Deutsch English Nederlands...
Страница 20: ...20...
Страница 23: ...23 C C C E C D B A 3 2 4 3 2 3 Deutsch English Nederlands...
Страница 25: ...25 B A 3 2 3 5 2 5 6 4 4 1 1 C D Deutsch English Nederlands...
Страница 27: ...27 A 1 2 3 4 5 5 Deutsch English Nederlands...
Страница 29: ...29 1 2 3 5 7 4 6 8 9 10 11 12 13 A B Deutsch English Nederlands...
Страница 55: ...55 1 2 3 4 5 7 8 6 16 10 10 11 13 12 14 15 17 18 19 Deutsch English Nederlands...
Страница 58: ...58...
Страница 59: ...59 Deutsch English Nederlands...