Installation Guide / Grounding System

3

Code-Compliant Planning and Installation Guide V 1.1 - Complying with AS/NZS1170.2-2011 AMDT 2-2016

Installation Instructions

PV Module Clamps Installation

The guide below is for PV module clamps installation. For PV Module installation, please follow manual provided by the 
manufacturer.

Before module and clamps installation, it is important to arrange how to position grounding clips to achieve earthing 
continuity between each PV modules and rails. The Clenergy recommends three different methods for Grounding 
Clips Layout Arrangement.

- Installation Instructions -

Figure 1

Figure 3 “Zig Zag” Grounding Clips Layout

Figure 2

Figure 4 “All Inter Clamps” Grounding Clips Layout

Method 1: “Even and Odd”

• When there is an even number of PV Modules in each 
row, install the grounding clips at the positions marked X in 
Figure 1, where the number of Grounding Clips = number 
of PV Modules. Figure shows 4 x PV Modules requiring 4 x 
grounding clips.

• When there is an odd number of PV Modules in each 
row, install grounding clips at positions marked X in Figure 
2, where the number of Grounding Clips = number of PV 
M 1. Figure shows 5 x PV Modules requiring 6 x 
grounding clips. 

Method 2: “Zig Zag”

Install the grounding clips at the positions marked X in 
Figure 3, where the number of Grounding Clips = number 
of PV M 1. Figure shows 5 x PV Modules requiring 6 
x grounding clips.

Notes:

• Please consult local PV Module supplier to check whether    
  “Zig Zag” grounding clips layout has any effect on PV       
  modules.
• Grounding clips are not suitable for Dual End Clamp.

Method 3: “All Inter Clamps”

Install the grounding clips at the positions marked X in 
Figure 4, where the number of Grounding Clips = (number 
of PV Modules -1) x 2. Figure shows 5 x PV Modules 
requiring 8 x grounding clips.

Содержание PV-ezRack Grounding system

Страница 1: ...Grounding System Code Compliant Planning and Installation Guide V 1 1 Complying with AS NZS1170 2 2011 AMDT 2 2016 Last Updated Apr 2022...

Страница 2: ...ck Product Warranty on our website Introduction Complying with all applicable local or national building codes including any that may supersede this manual Ensuring that PV ezRack and other products a...

Страница 3: ...Hex Head drive bit Torque Spanner Tape String Marker Pen Spanner Tools and Components Components ER EC ST Standard End Clamp ER IC ST Standard Inter Clamp C U 30 46 G Universal Clamp with Grounding cl...

Страница 4: ...the grounding clips at the positions marked X in Figure 1 where the number of Grounding Clips number of PV Modules Figure shows 4 x PV Modules requiring 4 x grounding clips When there is an odd number...

Страница 5: ...clips are the same as those for 2 rows of rails There are two types of clamps for PV Modules Installation Option 1 Standard Inter and End Clamps Place the first PV Module on the Rail according to you...

Страница 6: ...mes of PV Modules are completely pressed against End and Inter Clamps and Grounding Clips Visually check that Grounding Clips are positioned properly Grounding Clips are intended for SINGLE USE ONLY O...

Страница 7: ...l Clamp into the rail channel and slightly lift the framed PV Module to ensure the Grounding Clip is properly positioned as shown in Figure 14 Note The gap between two adjacent PV Modules generated by...

Страница 8: ...mum size is 10 mm2 insert the conductor into the Copper Channel and tighten the bolt M6 14 with 5 6 N m to ensure the earthing cable is tight Note Please check the electrical resistance between rail a...

Страница 9: ...St Clayton VIC 2168 Australia Phone 61 3 9239 8088 Email sales clenergy com au Web www clenergy com au Clenergy Clenergy_global ClenergyClub Clenergy ClenergyGlobal ClenergyClub ClenergyAUS A Clenergy...

Отзывы: