![Clenergy PostMount 6-A Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/clenergy/postmount-6-a/postmount-6-a_installation-manual_2622517008.webp)
Unit 1, 10 Duerdin St, Clayton VIC 3168, Australia
Tel: +61 3 9239 8088 Fax: +61 3 9239 8024
E-mail: [email protected] www.clenergy.com.au
7
page
of 12
Installation Instruction
4.3 PM6-A Rectangular Tube-Master Installation
4.3.1 Fix the Rectangular Tube-Master at Steel Cap
Assembly with M20*160 hex bolt, M20 nut, plain
washer 20, and spring washer 20. See the mark
①
.
4.3.2 Fix the Adjustable Tube at Rectangular Tube-
Master with M20*160 hex bolt, plain washer 20,
and spring washer 20, M20 nut. See the mark
②
.
4.3.3 Fix the Adjustable Tube at Steel Cap Assembly
with M20*160 hex bolt, M20 nut, plain washer 20,
and spring washer 20. See the mark
③
.
Realized the angle adjustment by position the bolt
in the differrent holes.
4.3.4 Fasten the Steel Cap Assembly to Pipe with
M20*210, M20*160 Hex Bolt, keep the Rectangular
Tube-Master parallel to the south-north by adjust the
Steel Cap Assembly
Recommended torque for M20 bolts is 210~220
N·m.
Note:
1: Adjust the angle of the allation, the angle of the Rectangular Tube-Master with 10°(6 holes
from up to bottom corresponds to 10° to 60° tilt angle) in order to make the assembly process
run smooth.
2: Using the adjustable washer to avoid the gap between the Rectangular Tube-Master and the
PM3/4-A Adjustable Tube. Unreliable connection is forbidden.
Содержание PostMount 6-A