RPH DUST COLLECTOR
Page 2
Figure 1
High Pressure Line
(Lower vacuum)
Low Pressure Line
(Higher vacuum)
Sequence Panel
Inlet Ducting
Supplied by user
Solenoid Bank
Access Covers
Diaphragm Pulse Valves
Pressure Regulator
Compressed air inlet
Exhaust Ducting
Supplied by user
Filter Cartridge
Differential Pressure
Panel Assembly
Manifold Drain Petcock
Dust Drums
Dust Drum Lids
Pulse Manifold
2.1 Footing
(Foundation)
2.0
ASSEMBLY AND INSTALLATION
2.1.1
The dust collector must be located on a sound
footing.
WARNING
Weight and bulk of the components may require
that erection and placement of the collector be
performed by personnel experienced with
handling structural steel, and able to safely
operate material handling equipment needed to
erect the collector. Failure to recognize and avoid
hazards associated with handling structural steel
could result in serious injury or death.
WARNING
All footings must be designed by a qualified
engineer. Inadequate footing could result in
hazardous shifting of the collector and ducting,
which could result in death or serious injury.