Clemco Apollo 60 HP Скачать руководство пользователя страница 6

APOLLO 60 HP SUPPLIED-AIR RESPIRATOR

Page 5

2.0

INSPECTION

! NOTICE

A Clemco respirator hose must be used with the
Apollo Respirator. If one is not available, it must
be ordered from an authorized distributor of
Clemco products.  Hoses are not included with
respirators, because blast operators often are
assigned personal respirators, while using com-
mon respirator hoses.

2.1

Component Checklist

2.1.1

Make sure that all the respirator components are

present. Each respirator box should contain the following:

• Helmet with chin strap, suspension and cape

attached

• Breathing tube assembly
• One of the following air control devices with belt:

Constant-Flow Connector
Air Control Valve
Cool-Air Tube
Climate-Control Tube

• Disconnect adaptor assembly

NOTE: Respirator hose (one or more alternate hoses)
must be ordered separately.

2.1.2

When all of these components are present, pre-

pare the respirator for operation per Section 3.0.

3.0

PREPARATION

3.1

Adjust Helmet Suspension per Section 6.2.

3.2

Lens Assembly

! WARNING

Never use the respirator without the fixed inner
lens and perforated outer lenses in place. The
fixed lens provides support for the window gas-
ket. If the gasket is not adequately supported,
leaks can occur which could permit entry of toxic
and hazardous dust or abrasive into the helmet.

3.2.1

The lens system is an important part of the respi-

rator assembly. The helmet is supplied with an inner lens,
secured by a thick rubber gasket. Held in place on top of
the inner lens by the window frame are up to five perforated
outer lenses.

3.2.2

Check that the inner lens is in place. (See Section

9.1)

3.2.3

The perforated outer lenses are secured to the

helmet by the window frame. As one lens becomes frosted
during blasting, it can be torn off to expose the next lens.
Check that the perforated outer lenses are in place. (See
Section 9.2)

3.3

Belt

3.3.1

Using the spring clip attached to the Constant-

Flow Connector, attach the connector to the belt slide. This
step is not required with alternate air control devices,
because the Air Control Valve is furnished with a hook-on
belt clip, and belts are attached to Cool Air Tubes and
Climate Control Tubes.

3.4

Breathing Tube Assembly

3.4.1

Attach the red end of the breathing tube to the

threaded air inlet fitting at the back of the helmet.

3.4.2

Attach the swivel connector on the black end, to

the Constant-Flow Connector, or alternate air control
device.

! WARNING

The red end of the breathing tube must attach to
the helmet, and the black end to the Constant-
Flow Connector or alternate air control valve.
Failure to properly attach the tube may increase
noise levels beyond OSHA limits.

3.4.3

Use the strap handle to carry or hang the respira-

tor. Never hold, carry or hang the respirator by the breath-
ing tube.  Mishandling the respirator in this manner may
damage the tube or helmet inlet. Any leaks or breaks in the
breathing tube will alter the air flow through the respirator
and affect user’s safety and comfort.

3.5

Respirator Hose

3.5.1

Use the disconnect adaptor assembly to attach

the respirator hose to the Constant-Flow Connector, or
alternate air control device. Using the adaptor provided,

Содержание Apollo 60 HP

Страница 1: ...ou are using a Clemco Distributor Parts and Maintenance Guide refer to the orange warnings insert preceding the Index before continuing with the following instructions CLEMCO INDUSTRIES CORP One Cable...

Страница 2: ...i rator 1 1 2 OSHA requires the employer to establish a com prehensive respiratory protection program per regulations 29 CFR 1910 134 a b and 29 CFR 1926 103 to include the following 1 Program coordin...

Страница 3: ...sup plied air respirator equipment by blasting opera tors and all personnel within the work site area Leadpoisoningcancausedeath OSHAhasstated that the permissible exposure limit of lead is 50 microgr...

Страница 4: ...ntenance manuals for information on use and maintenance of these respirators 1 5 Special Use Limitations 1 5 1 Air pressure at the point of attachment the point of attachment is where the respirator s...

Страница 5: ...s conditions Constant Flow Connector CFC Provides non adjust able volume of supplied air within the cfm range required by OSHA Air Control Valve ACV Enables the user to a d j u s t the volume of suppl...

Страница 6: ...r lens by the window frame are up to five perforated outer lenses 3 2 2 Check that the inner lens is in place See Section 9 1 3 2 3 The perforated outer lenses are secured to the helmet by the window...

Страница 7: ...necessary safety and monitoring devices plus suitable in line air filters and purifying equipment to assure breathing air quality Refer ence OSHA Regulations 29 CFR 1910 134 d and 29 CFR 1926 103 f 4...

Страница 8: ...attached If the regulator is adjusted with static pressure no air flow pressure may drop below the required pressure when the respirator is connected and may result in low air flow Setting the pressur...

Страница 9: ...e positioned and maintained without any interference from items such as hair facial hair or shirt collars between the collar and user s neck 5 9 Pull the cape down to fully extend it and connect the f...

Страница 10: ...Try the helmet on for fit and readjust if necessary 6 2 9 Check that the chin strap is in place then reattach the cape onto the helmet following the instructions in Section 9 4 7 0 MAINTENANCE PROGRAM...

Страница 11: ...to circulate to dry condensation from the cape and from inside the helmet 7 5 2 Long term storage 7 5 2 1 After inspection cleaning and thorough drying and after necessary repairs are made the cape s...

Страница 12: ...eplacing Perforated Outer Lenses Figure 4 9 2 1 Up to five outer lenses can be installed at one time For maximum visibility install only enough lenses to last during a work period 9 2 2 Preparing lens...

Страница 13: ...tructions 9 6 Window Frame 9 6 1 The window frame must be replaced when it becomes difficult to maintain a seal or to keep the latch closed When replacing the window frame the acoustical foam inside t...

Страница 14: ...includes items 6 and 7 04398 6 Adaptor 3 8 hose to 3 8 pipe 00022 7 Union 3 8 hose to 3 8 hose 01020 8 Disconnect 1 4 female 00025 9 Adaptor 3 8 hose to 1 4 pipe 01019 10 Acoustical foam kit sides 04...

Отзывы: