Clemco Apollo 60 HP Скачать руководство пользователя страница 5

APOLLO 60 HP SUPPLIED-AIR RESPIRATOR

Page 4

bels. (42 CFR part 84.140) When any exterior noise
causes the internal noise level to exceed 80 decibels, the
user must wear additional hearing protection. A variety of
hearing protectors can be worn with the respirator.

1.7

Description

1.7.1

The Clemco Apollo 60 Supplied-Air Respirator is

approved by the National Institute of Occupational Safety
and Health (NIOSH).

! WARNING

OSHA/NIOSH approval applies only when this
supplied-air respirator is used as a complete
system. Do not make any non-approved modifi-
cation, deletion, or substitution. Non-approved
components voids the NIOSH approval and may
permit ingress of toxic and hazardous dust, and
result in toxic poisoning and respiratory disease.

1.7.2

The respirator comes with one of four air control

devices that permit safe, comfortable blast cleaning under
various conditions.

Constant-Flow Connector (CFC): Provides non-adjust-

able volume of supplied air, within the cfm range required
by OSHA.

Air Control Valve (ACV): Enables the user to a d j u s t

the volume of supplied air, within the cfm range required by
OSHA. It is for use in areas where the air temperature is
comfortable.

Cool-Air Tube (CAT): Used in warm climates to enable

the user to adjust supplied air to cooler temperatures.

Climate Control Tube (CCT): Enables the user to adjust

supplied air to warmer or cooler temperatures.

1.7.3

Low Pressure Conversion Kit: This optional ac-

cessory kit contains parts and instructions to convert the
Apollo 60 HP, (respirator for use with Grade “D” Com-
pressed Air) to Apollo 60 LP (respirator for use with
ambient air pump). The kit is listed in Section 10.1.

Figure 1.

General Arrangement

of Operator Safety

and Comfort Components

Apollo 60

Supplied-Air

Respirator

Blast

Suit

Breathing-Air

Tube Assembly

Carbon

Monoxide

Alarm

Climate
Control

Tube

Blast Suit

Respirator

Supply Hose

CPF-20

Particulate

Filter

Breathing-Air

Source

Gloves

Содержание Apollo 60 HP

Страница 1: ...ou are using a Clemco Distributor Parts and Maintenance Guide refer to the orange warnings insert preceding the Index before continuing with the following instructions CLEMCO INDUSTRIES CORP One Cable...

Страница 2: ...i rator 1 1 2 OSHA requires the employer to establish a com prehensive respiratory protection program per regulations 29 CFR 1910 134 a b and 29 CFR 1926 103 to include the following 1 Program coordin...

Страница 3: ...sup plied air respirator equipment by blasting opera tors and all personnel within the work site area Leadpoisoningcancausedeath OSHAhasstated that the permissible exposure limit of lead is 50 microgr...

Страница 4: ...ntenance manuals for information on use and maintenance of these respirators 1 5 Special Use Limitations 1 5 1 Air pressure at the point of attachment the point of attachment is where the respirator s...

Страница 5: ...s conditions Constant Flow Connector CFC Provides non adjust able volume of supplied air within the cfm range required by OSHA Air Control Valve ACV Enables the user to a d j u s t the volume of suppl...

Страница 6: ...r lens by the window frame are up to five perforated outer lenses 3 2 2 Check that the inner lens is in place See Section 9 1 3 2 3 The perforated outer lenses are secured to the helmet by the window...

Страница 7: ...necessary safety and monitoring devices plus suitable in line air filters and purifying equipment to assure breathing air quality Refer ence OSHA Regulations 29 CFR 1910 134 d and 29 CFR 1926 103 f 4...

Страница 8: ...attached If the regulator is adjusted with static pressure no air flow pressure may drop below the required pressure when the respirator is connected and may result in low air flow Setting the pressur...

Страница 9: ...e positioned and maintained without any interference from items such as hair facial hair or shirt collars between the collar and user s neck 5 9 Pull the cape down to fully extend it and connect the f...

Страница 10: ...Try the helmet on for fit and readjust if necessary 6 2 9 Check that the chin strap is in place then reattach the cape onto the helmet following the instructions in Section 9 4 7 0 MAINTENANCE PROGRAM...

Страница 11: ...to circulate to dry condensation from the cape and from inside the helmet 7 5 2 Long term storage 7 5 2 1 After inspection cleaning and thorough drying and after necessary repairs are made the cape s...

Страница 12: ...eplacing Perforated Outer Lenses Figure 4 9 2 1 Up to five outer lenses can be installed at one time For maximum visibility install only enough lenses to last during a work period 9 2 2 Preparing lens...

Страница 13: ...tructions 9 6 Window Frame 9 6 1 The window frame must be replaced when it becomes difficult to maintain a seal or to keep the latch closed When replacing the window frame the acoustical foam inside t...

Страница 14: ...includes items 6 and 7 04398 6 Adaptor 3 8 hose to 3 8 pipe 00022 7 Union 3 8 hose to 3 8 hose 01020 8 Disconnect 1 4 female 00025 9 Adaptor 3 8 hose to 1 4 pipe 01019 10 Acoustical foam kit sides 04...

Отзывы: