Figure 6.

(2)

(1)

(3, 4, 5)

(6)

(7)

(9)

(8)

(10)

(11)

(12)

(14)

(13)

(15)

(16)

(17)

(18)

(24)

(19)

(20)

(22)

(23)

(21)

Page 13

10.2

Supplied-Air Respirator, Figure 6

Item Description

Stock No.

  1.

Constant-flow connector, HP (alternate),

without belt ........................................ 21415

  2.

Belt assembly, 2" ..................................... 04430

  3.

Respirator hose, 3/8" x 25 ft. (alternate),

includes items 6 and 7 ....................... 04397

  4.

Respirator hose, 3/8" x 50 ft. (alternate),

includes Items 6 and 7 ...................... 04415

  5.

Respirator hose, 3/8" x 100 ft. (alternate),

includes items 6 and 7 ....................... 04398

  6.

Adaptor, 3/8" hose to 3/8" pipe ................ 00022

  7.

Union, 3/8" hose to 3/8" hose .................. 01020

  8.

Disconnect, 1/4" female ........................... 00025

  9.

Adaptor, 3/8" hose to 1/4" pipe ................ 01019

10.

Acoustical foam kit, sides ........................ 04369

11.

Gasket, window ........................................ 04452

12.

Inner lens, .040" package of 5 ................. 04367

13.

Outer lens, .0075", perforated,

package of 25 .................................... 04361

14.

Window frame kit ..................................... 08741

15.

Chin strap ................................................. 04460

16.

Handle strap ............................................. 03623

17.

Suspension .............................................. 10532

18.

Cape attachment strap ............................ 10534

19.

Cape with inner collar .............................. 04435

20.

Breathing tube assembly w/molded ends 21550

21.

Washer, breathing tube, package of 6 ..... 04370

22.

Inner collar kit ........................................... 08740

23.

Window latch kit ....................................... 04368

24.

O-Ring, .864" ID x 1.004" OD .................. 21561

Содержание Apollo 60 HP

Страница 1: ...ou are using a Clemco Distributor Parts and Maintenance Guide refer to the orange warnings insert preceding the Index before continuing with the following instructions CLEMCO INDUSTRIES CORP One Cable...

Страница 2: ...i rator 1 1 2 OSHA requires the employer to establish a com prehensive respiratory protection program per regulations 29 CFR 1910 134 a b and 29 CFR 1926 103 to include the following 1 Program coordin...

Страница 3: ...sup plied air respirator equipment by blasting opera tors and all personnel within the work site area Leadpoisoningcancausedeath OSHAhasstated that the permissible exposure limit of lead is 50 microgr...

Страница 4: ...ntenance manuals for information on use and maintenance of these respirators 1 5 Special Use Limitations 1 5 1 Air pressure at the point of attachment the point of attachment is where the respirator s...

Страница 5: ...s conditions Constant Flow Connector CFC Provides non adjust able volume of supplied air within the cfm range required by OSHA Air Control Valve ACV Enables the user to a d j u s t the volume of suppl...

Страница 6: ...r lens by the window frame are up to five perforated outer lenses 3 2 2 Check that the inner lens is in place See Section 9 1 3 2 3 The perforated outer lenses are secured to the helmet by the window...

Страница 7: ...necessary safety and monitoring devices plus suitable in line air filters and purifying equipment to assure breathing air quality Refer ence OSHA Regulations 29 CFR 1910 134 d and 29 CFR 1926 103 f 4...

Страница 8: ...attached If the regulator is adjusted with static pressure no air flow pressure may drop below the required pressure when the respirator is connected and may result in low air flow Setting the pressur...

Страница 9: ...e positioned and maintained without any interference from items such as hair facial hair or shirt collars between the collar and user s neck 5 9 Pull the cape down to fully extend it and connect the f...

Страница 10: ...Try the helmet on for fit and readjust if necessary 6 2 9 Check that the chin strap is in place then reattach the cape onto the helmet following the instructions in Section 9 4 7 0 MAINTENANCE PROGRAM...

Страница 11: ...to circulate to dry condensation from the cape and from inside the helmet 7 5 2 Long term storage 7 5 2 1 After inspection cleaning and thorough drying and after necessary repairs are made the cape s...

Страница 12: ...eplacing Perforated Outer Lenses Figure 4 9 2 1 Up to five outer lenses can be installed at one time For maximum visibility install only enough lenses to last during a work period 9 2 2 Preparing lens...

Страница 13: ...tructions 9 6 Window Frame 9 6 1 The window frame must be replaced when it becomes difficult to maintain a seal or to keep the latch closed When replacing the window frame the acoustical foam inside t...

Страница 14: ...includes items 6 and 7 04398 6 Adaptor 3 8 hose to 3 8 pipe 00022 7 Union 3 8 hose to 3 8 hose 01020 8 Disconnect 1 4 female 00025 9 Adaptor 3 8 hose to 1 4 pipe 01019 10 Acoustical foam kit sides 04...

Отзывы: