Troubleshooting
60
P2398PM |
2019-12
Apex Tool Group
5
EN
Troubleshooting
Problem
Possible cause
Measure
General tool
Tool does not start.
Speed not parameter-
ized.
Check Linking group.
In the mPro mode, select
Navigator >
Standard
or
Navigator > Basic
.
Check FastApps.
In the FastApps mode:
>
>
must be selected.
Tool does not start with
counterclockwise rota-
tion activated.
With counterclockwise
rotation, parameter for
speed is set to 0 rpm.
Parameterizing the speed for counterclockwise
rotation.
On the control screen
Standard > Standard Application Builder >
Tool Groups
Tool light disabled.
Disabled by parameter
setting.
Parameterizing the tool light:
On the control screen
Advanced > Tool Group > Extended Tool
Settings
To activate the tool light:
>
>
Control menu on tool not
enabled or only partially
enabled.
Disabled by parameter
setting.
To enable the control menu:
>
>
Idle speed not reached.
Battery voltage is too low.
Use fully charged battery.
Expected number of run-
downs is not achieved
with one charge of the
battery.
Battery is not fully
charged.
Use fully charged battery.
The warning threshold for
undervoltage is not set to
the minimum value.
On the control screen
Tool Setup > Tool Settings
, reduce the
Undervoltage (V)
.
To set the warning threshold:
>
>
High torque is needed
during a fastening
sequence, e.g., for
coated fasteners.
If a high torque is needed for a longer period of
time, e.g., for several turns, the number of run-
downs that can be achieved with one battery
charge will be significantly reduced.
Battery has too many
charging cycles.
After
800 charging cycles, the capacity is
reduced to approx. 60%
.
Software does not boot.
Use recovery stick. Contact the service
department at Apex Tool Group.