Menus and Functions
22
P2398PM |
2019-12
Apex Tool Group
3
EN
3.6.4
Advanced settings
>
>
>
Fig. 3-12: Submenu – Advanced Settings
Button
Description
Torque shutoff
Sequence 31: Shut-off torque controlled tightening sequence with torque and rotation
angle check. See 4 Tightening sequence, page 56.
Angle shutoff
Sequence 51: Shut-off angle controlled tightening sequence with rotation angle and
torque check. See 4 Tightening sequence, page 56.
Button
Description
For a torque shutoff, enter the shut-off torque.
For an angle shutoff, enter the shut-off angle.
Once the value has been reached, the tightening process is ended. This setting option
is the same as in the menu 3.6.1 Configuring FastApps, page 19.
Note
If the shut-off value is entered here in the
Advanced Settings
menu, the minimum and
maximum torque, the minimum and maximum angle, as well as the threshold torque,
are not calculated automatically.
Display of the maximum torque.
Display of the minimum torque.
The minimum torque can not be greater than the shut-off torque and must be at least
as great as the threshold torque.
Enter the threshold torque.
Enter the maximum angle.
1
ADV
ADV
Содержание CellCore CCBA
Страница 65: ......