7
TRANSDUCER SPECIFICATIONS
MAXIMUM TORQUE CAPACITY
147 ft. lbs. (200 Nm)
OUTPUT VOLTAGE (Vo)
2 Millivolts per volt at maximum torque capacity
BRIDGE RESISTANCE (Rbr)
700 ohms (nominal) can be used with 350 and 700 ohm strain gage equipment*
TRANSDUCER CABLE
No. 203450
CALIBRATION INSTRUCTIONS
ANGLE HEAD SIZE FULL SCALE VALUE (FS)
FT. LBS. Nm
Straight
147.5
200
"V"
196.2
266
"X"
312.7
424
In order to calculate the calibration value for the system in % full scale, the following formula may be used:
% FS = Rbr
1
1
------------------ X ----- X -----
2(Rcal) + Rbr Vo
2
Where Rcal = Calibration Resistor Value in ohms of the torque monitor used.
The following is an example of a 75 series right angle tool, a "V" head and a torque monitor with a 110,000ohm calibra-
tion resistor.
The values are: FS = 196.2 ft. lbs.
Rbr = 700ohm
Vo = .002
Rcal = 110,000ohm
700ohm
1
1
% FS = --------------------------- X ------ X ----- = 79.3%
2(110,000ohm) + 700ohm .002
2
Calibration Value = 196.2 (.793) = 155.6 ft. lbs.
*Calculated calibration value should be doubled if a torque monitor designed for use with a 350ohm bridge resistance
transducer is used.
A
A
B
B
C
C
D
D
BLACK
GREEN
RED
WHITE
TOOL RECEPTACLE
CABLE CONNECTORS
R
WIRING DIAGRAM
E
E
F
F
(+) SIGNAL
(-) SIGNAL
SHIELD
(+) EXCITATION
(-) EXCITATION
Ro/2
Rm/2
R
R
R
t
C
t
C
Ro/2
Rm/2
Rcal
R= Gage Resistance
Rm= Modulus Resistor
Ro= Output Scaling Resistor
Rm & Ro may be omitted
Rcal= Shunt Calibration Resistor
Содержание 75NLTVCE Series
Страница 18: ...18...
Страница 19: ...19 NOTES...
Страница 20: ...20 670 Industrial Drive Lexington SC 29072 Phone 803 359 1200 Fax 803 359 2013...