OPERATING INSTRUCTIONS
FOR YOUR SAFETY AND THE SAFETY OF OTHERS, READ AND UNDERSTAND THE
SAFETY RECOMMENDATIONS ON PAGES 2 thru 4 BEFORE OPERATING A NUTRUNNER.
TORQUE ADJUSTMENT
The 35NLTVC nutrunner is designed to develop maxi-
mum rated torque at 90 psig. The torque setting is achieved
by entering a number within the tool's torque range into the
torque control monitor. See catalog for torque range of
tool.The torque setting entered into the torque control
monitor must not exceed maximum torque range of tool or
the automatic shut-off device will not function and the tool
will operate as a stall tool. Operator should be prepared to
resist torque reaction until throttle is released.
THROTTLE POSITION
The throttle lever may be repositioned to accomodate
proper location for task and to avoid entrapment. Reposi-
tioning of the angle head is done by adding or removing
head positioning shims. Retighten head with proper wrench.
AIR SUPPLY
For maximum performance, use a 3/8" I.D. air hose no
longer than 8' in length. If additional length is required, a
1/2" or larger hose should be connected to the 3/8" hose.
Being careful to avoid endangering adjacent personnel or
yourself, the air hose should be cleared of accumulated
dirt and moisture, then one (1) teaspoonful of 10W ma-
chine oil should be poured into the tool's air inlet before
connecting the hose to the tool.
LUBRICATION
An automatic in-line filter-lubricator is recommended as it
increases tool life and keeps the tool in sustained opera-
tion. The in-line lubricator should be regularly checked and
filled with a good grade of 10W machine oil. Proper
adjustment of the in-line lubricator is performed by placing
a sheet of paper next to the exhaust ports and holding the
throttle open approximately 30 seconds. The lubricator is
properly set when a very light stain of oil collects on the
paper. Excessive amounts of oil should be avoided.
Application of the tool should govern how frequently it is
greased. It is recommended that the idler gears and angle
gears receive a generous amount of NLGI 2-EP grease
after 40 hours of operation.
The angle head must be removed (left hand threads) from
the gear case and grease is applied through the hex in the
gear spider to lubricate the idler gears. Grease is applied
to the angle gears through the grease fitting located in the
angle head housing. Use only a low pressure grease gun.
STORAGE
In the event that it becomes necessary to store the tool for
an extended period of time (overnight, weekend, etc.), it
should receive a generous amount of lubrication and run
for a few seconds until the oil is distributed throughout the
tool. The tool should be stored in a clean and dry environ-
ment.